Enhanced performance in the determination of ibuprofen 1-β-O-acyl glucuronide in urine by combining high field asymmetric waveform ion mobility spectrometry with liquid chromatography-time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(23 citation statements)
references
References 19 publications
0
23
0
Order By: Relevance
“…We employed FAIMS chips from Owlstone (Cambridge, UK): the early version (I) with g = 35 μm, installed on the Thermo Scientific LTQ ion trap mass spectrometer [35], and current ultraFAIMS (II) with g = 100 μm, coupled to the Agilent 6538 time-of-flight (ToF) MS platform [38]. One difficulty of integrating FAIMS using large He or H 2 fractions with commercial MS instruments is the aspiration of hard-to-evacuate light gases into MS vacuum, where they challenge pumping designed for air.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…We employed FAIMS chips from Owlstone (Cambridge, UK): the early version (I) with g = 35 μm, installed on the Thermo Scientific LTQ ion trap mass spectrometer [35], and current ultraFAIMS (II) with g = 100 μm, coupled to the Agilent 6538 time-of-flight (ToF) MS platform [38]. One difficulty of integrating FAIMS using large He or H 2 fractions with commercial MS instruments is the aspiration of hard-to-evacuate light gases into MS vacuum, where they challenge pumping designed for air.…”
Section: Methodsmentioning
confidence: 99%
“…As the FAIMS technology has advanced, the minimum gap width ( g ) has been reduced from ~2 mm to 0.5 mm [3133] and, recently, to 35 or 100 μm in microchips with multiple channels for concurrent ion processing [3438]. By the Paschen law [29], the breakdown field for any gas goes up at lower gN .…”
Section: Introductionmentioning
confidence: 99%
“…There was a 10-fold improvement of both mass-selected and drift time-selected chromatogram for the HPLC-IMS-TOF combination over the mass-selected chromatogram when no IMS was used (Figure 4). This can be attributed to the reduction of chemical noise by ion mobility spectrometry though the absolute intensity was reduced [49][50][51]. Two concerns about multidimensional separation with HPLC-IMS-MS are the limit of detection and method of quantification.…”
Section: Sampling Rate Of Hadamard Transform Ion Mobility Spectrometementioning
confidence: 99%
“…Given that LC separations have a timescale of minutes and time-of-flight (TOF) detection occurs in microseconds, IM is easily integrated with its millisecond regime without affecting the timescale of the existing LC-MS/MS method, by adding an extra, orthogonal separation dimension. Relatively few studies have been published on the use of LC-IM-MS/MS so far [33][34][35][36][37][38], but this number is expected to increase considerably in the next years. While retention time (t R ), drift time (t d ) and mass-tocharge (m/z) provide key analytical determinants (e.g.…”
Section: Introductionmentioning
confidence: 99%