Enhanced Oral Bioavailability of Pueraria Flavones by a Novel Solid Self-microemulsifying Drug Delivery System (SMEDDS) Dropping Pills

Abstract: To improve bioavailability of pueraria flavones (PF), a self-microemulsifying drug delivery system (SMEDDS) dropping pills composed of PF, Crodamol GTCC, Maisine 35-1, Cremophor RH 40, 1,2-propylene glycol and polyethylene glycol 6000 (PEG6000) was developed. Particle size, zeta potential, morphology and in vitro drug release were investigated, respectively. Pharmacokinetics, bioavailability of PF-SMEDDS dropping pills and commercial Yufengningxin dropping pills were also evaluated and compared in rats. Puerar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 17 publications
(16 reference statements)
2
9
0
Order By: Relevance
“…The concentration of micelle solution was maintained at 1.50 mg/ml. The zeta potential and particle size of micelles were evaluated with a dynamic light scattering (DLS) particle size analyser with a scattering angle of 90° (Zetasizer Nano ZS, λ = 633 nm, Malvern Instruments, Malvern, UK) at 25˚C.…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of micelle solution was maintained at 1.50 mg/ml. The zeta potential and particle size of micelles were evaluated with a dynamic light scattering (DLS) particle size analyser with a scattering angle of 90° (Zetasizer Nano ZS, λ = 633 nm, Malvern Instruments, Malvern, UK) at 25˚C.…”
Section: Methodsmentioning
confidence: 99%
“…The zeta potential and particle diameter of DTX-SA-BSPs copolymer micelles were measured using a dynamic light scattering (DLS) particle size analyzer with a scattering angle of 90° (Zetasizer Nano ZS, Malvern Instruments, UK) at 25°C, as described [28]. All the experiments were carried out in triplicate and data were expressed as mean values with their standard deviations (S.D.…”
Section: Methodsmentioning
confidence: 99%
“…Blood sample (0.5 mL) was collected in heparinized tubes from the retro-orbital plexus while the rats were anesthetized under diethyl ether inhalation after 0, 10, 30, 60, 120, 180, 240, 300, and 360 min of vein injection. The blood sample was then separated from the heparinized blood by centrifugation using a centrifuge 5415C (Eppendorf, Germany), and stored at -20°C until analysis [28]. All the data were analyzed using the DAS 2.1 pharmacokinetic software (a program by Chinese Pharmacological Society, China), and the results were represented as mean values with standard deviations.…”
Section: Methodsmentioning
confidence: 99%
“…The zeta potential and particle diameter of the DTX-SA-BSPs copolymer micelles were assessed on dynamic light scattering particle size analyzer with a scattering angle of 90 • (Zetasizer Nano ZS, Malvern Instruments, Malvern, UK) at 25 • C [43]. All experiments were carried out in triplicates, and data were expressed as mean values with their standard deviations.…”
Section: Particle Size and Zeta Potentialmentioning