2018
DOI: 10.1016/j.talanta.2017.09.082
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced electrochemical response of carbon quantum dot modified electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(27 citation statements)
references
References 43 publications
0
24
0
1
Order By: Relevance
“…The direct 13 C polarization spectrum of the CQDs just reveals the graphitic section of sp 2 at a chemical shi of 128.3 ppm in a magnetic eld of 7 T, nevertheless, in the case of recording spectrum at 14 T, this spectrum presented further signals at 113.7 and 164.7 ppm, which are allocated to the lactol type carbon belonging to 5 and or six membered lactol ring and ester carbonyl carbon or the carboxylic acid group (-CO-O-R or -CO 2 H) based on the results obtained in previous studies on graphite oxide materials. 96…”
Section: Nuclear Magnetic Resonance Spectrummentioning
confidence: 99%
See 1 more Smart Citation
“…The direct 13 C polarization spectrum of the CQDs just reveals the graphitic section of sp 2 at a chemical shi of 128.3 ppm in a magnetic eld of 7 T, nevertheless, in the case of recording spectrum at 14 T, this spectrum presented further signals at 113.7 and 164.7 ppm, which are allocated to the lactol type carbon belonging to 5 and or six membered lactol ring and ester carbonyl carbon or the carboxylic acid group (-CO-O-R or -CO 2 H) based on the results obtained in previous studies on graphite oxide materials. 96…”
Section: Nuclear Magnetic Resonance Spectrummentioning
confidence: 99%
“…Finally, the decreased LOD equals 2.7 mM for DA. 136 Moreover, Yola et al (2019) developed an electrochemical sensor on the basis of the molecularly imprinted polymer/ graphitic carbon nitride/N-doped carbon dots composite (MIP/g-C 3 N 4 /NCDS) and has been applied to detect EP in the urine samples. In the following, EP imprinted voltammetric sensor on the graphitic carbon nitride/NCDS has been synthesized in the presence of 100.0 mM pyrrole consisting of 25.0 mM EP through CV.…”
Section: Applications Of Cqds and Gqdsmentioning
confidence: 99%
“…The 13 C direct polarization spectra show that the unique signal in each sample is present at a δ 13 C around 110-130 ppm ( Figure 9); this is common in graphitic materials [77][78][79][80]. The CD-RO and CD-PL samples once again show the highest and sharpest NMR signal, related to the higher degree of order within the organic structure.…”
Section: Characterisation Of Demineralised Char Concentratesmentioning
confidence: 89%
“…Drop casting of carbon-based quantum particles, obtained by a green variant of Hummers' method, onto glassy carbon electrode (GCE) allows to construct a sensor for dopamine with a detection limit of 2.7 μM. 173 The sensitivity could be improved by employing β-cyclodextrin (CD) reaching a LoD of 140 nM. 174 N-doped CQDs, formed using diethanolamine as nitrogen and carbon source, coated onto GCE resulted finally in a dopamine sensor with a limit of detection of 1.2 nM 175 for use in urine and blood serum but also for eventual characteristic of living systems.…”
Section: Chemical Sensorsmentioning
confidence: 99%