2011
DOI: 10.1016/j.jlp.2010.06.016
|View full text |Cite
|
Sign up to set email alerts
|

Engineering layout of fuel tanks in a tank farm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…From a land‐use perspective, the location of hazardous units (i.e., units with a credible amount of hazardous materials) is selected so that given a primary accident, its physical effects (e.g., thermal radiation, overpressure, etc.) are not likely to affect and/or damage other safety‐critical units or structures . In this regard, placing hazardous units such as storage tanks in lower level areas such as pits would be advisable.…”
Section: Application Of Inherent Safety Concepts To Domino Effectsmentioning
confidence: 99%
See 1 more Smart Citation
“…From a land‐use perspective, the location of hazardous units (i.e., units with a credible amount of hazardous materials) is selected so that given a primary accident, its physical effects (e.g., thermal radiation, overpressure, etc.) are not likely to affect and/or damage other safety‐critical units or structures . In this regard, placing hazardous units such as storage tanks in lower level areas such as pits would be advisable.…”
Section: Application Of Inherent Safety Concepts To Domino Effectsmentioning
confidence: 99%
“…are not likely to affect and/or damage other safety-critical units or structures. (11) In this regard, placing hazardous units such as storage tanks in lower level areas such as pits would be advisable.…”
Section: Introductionmentioning
confidence: 99%
“…Another recent study (Sengupta and Gupta, 2011) dealt with the location of tanks in a tank farm and safe separation distances. Different methods available in the literature for calculating the heat flux at various distances were used in order to find safe distances.…”
Section: Separation Distances: Fire Modelsmentioning
confidence: 99%
“…LDS consists of a polyethylene film 1 mm thick, laid under the bottom of the tank at a depth of 70 cm and a drainage pipe connected to the leak detection well (Fig. 1) [2][3]. During the operation of TB emissions and leakages are released into the air, waste water and soil.…”
Section: Introductionmentioning
confidence: 99%