Engineering and implementation of the new diffractometer – D3 – for the macromolecular crystallography beamlines of the Swiss Light Source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2015
2015

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…PRIGo was installed at beamline X06DA (PXIII) at the Swiss Light Source in January 2012 and is now fully integrated into the new data acquisition user interface DA+ (E. Panepucci et al, unpublished). Its compact design and small space envelope at large angles (Maag et al, 2013) (Fig. 5) maximize the achievable angular range but self-shadowing on the detector and potential collisions with beamline devices such as the collimator or the beam stop still impose angular restrictions.…”
Section: Integration Of Prigo At Beamline X06da (Pxiii) At Slsmentioning
confidence: 99%
“…PRIGo was installed at beamline X06DA (PXIII) at the Swiss Light Source in January 2012 and is now fully integrated into the new data acquisition user interface DA+ (E. Panepucci et al, unpublished). Its compact design and small space envelope at large angles (Maag et al, 2013) (Fig. 5) maximize the achievable angular range but self-shadowing on the detector and potential collisions with beamline devices such as the collimator or the beam stop still impose angular restrictions.…”
Section: Integration Of Prigo At Beamline X06da (Pxiii) At Slsmentioning
confidence: 99%
“…The design thus could be kept as modular as possible, to both vibrationally isolate components from each other as well as maintain a high degree of configurability. Some details of the PSI construction and engineering have been described by Maag et al (2013).…”
Section: Hardwarementioning
confidence: 99%
“…To ensure that the PRIGo multi-axis goniometer (Glettig et al, 2011) can be integrated into the diffractometer set-up without any further modifications of the diffractometer, extensive integration studies were carried out during the construction phase of the single-axis system (Maag et al, 2013). In these studies, potential collisions with the lamp, the microscope, the beam-shaping devices and the cryogenic system were investigated.…”
Section: Sample Environmentmentioning
confidence: 99%
See 1 more Smart Citation