Energy transfer from rhodamine 6G to thionine in an anionic microemulsion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…Fluorescence lifetimes were measured using a time-correlated single photon counting (TCSPC) technique (Horiba Jobin Yvon), with a pulsed laser diode as excitation source at 560 nm (NanoLed, Horiba) and a pulse rate of 1 MHz in a 90° arrangement to a TBX-4 detector. The detector was set to 636 nm, and the aperture of the band-pass was set to its maximum value (24.9 nm) due to the well-known weak fluorescence intensity of thionine samples. , The instrument was set in the Reverse TAC mode, where the first detected photon represented the start signal for the time-to-amplitude converter (TAC), and the excitation pulse triggered the stop signal. DAS6 decay analysis software was used for lifetime calculation.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescence lifetimes were measured using a time-correlated single photon counting (TCSPC) technique (Horiba Jobin Yvon), with a pulsed laser diode as excitation source at 560 nm (NanoLed, Horiba) and a pulse rate of 1 MHz in a 90° arrangement to a TBX-4 detector. The detector was set to 636 nm, and the aperture of the band-pass was set to its maximum value (24.9 nm) due to the well-known weak fluorescence intensity of thionine samples. , The instrument was set in the Reverse TAC mode, where the first detected photon represented the start signal for the time-to-amplitude converter (TAC), and the excitation pulse triggered the stop signal. DAS6 decay analysis software was used for lifetime calculation.…”
Section: Methodsmentioning
confidence: 99%
“…The detector was set to 636 nm, and the aperture of the band-pass was set to its maximum value (24.9 nm) due to the well-known weak fluorescence intensity of thionine samples. 45,46 The instrument was set in the Reverse TAC mode, where the first detected photon represented the start signal for the time-to-amplitude converter (TAC), and the excitation pulse triggered the stop signal. DAS6 decay analysis software was used for lifetime calculation.…”
Section: Introductionmentioning
confidence: 99%
“…limitation, we combine multiple dyes in a single laser to extend the emission to near-infrared wavelengths and achieve multi-wavelength random laser operation through energy transfer. E cient energy transfer between two dyes occurs when their spectral pro les overlap effectively [3,4]. When the donor dye is excited, it transfers its excitation energy to the acceptor dye through a non-radiative process.…”