1987
DOI: 10.1103/physrevb.36.8115
|View full text |Cite
|
Sign up to set email alerts
|

Energy transfer between europium and manganese close pairs in monocrystalline sodium bromide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
3
1

Year Published

1990
1990
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(5 citation statements)
references
References 11 publications
1
3
1
Order By: Relevance
“…5. Similar phenomena were observed in other Eu 2 + /Mn 2 + -codoped phosphors and were attributed to Eu 2 + /Mn 2 + close paring [7,[14][15][16][17]. Here, we suggest the simple reason for this interesting observation is the local inhomogeneous distribution of Eu 2 + ions around Mn 2 + sites which can give rise to the perturbation of these sites and thus violation of the Mn 2 + selection rules and enhance the Mn 2 + red emission.…”
Section: Resultssupporting
confidence: 75%
“…5. Similar phenomena were observed in other Eu 2 + /Mn 2 + -codoped phosphors and were attributed to Eu 2 + /Mn 2 + close paring [7,[14][15][16][17]. Here, we suggest the simple reason for this interesting observation is the local inhomogeneous distribution of Eu 2 + ions around Mn 2 + sites which can give rise to the perturbation of these sites and thus violation of the Mn 2 + selection rules and enhance the Mn 2 + red emission.…”
Section: Resultssupporting
confidence: 75%
“…Moreover, they also indicate that such a line does not disappear even after heating the crystal at 800 K for several hours. Despite the similarity with some of the results reported here, Rubio et al [24] have not identified any EPR line with AH,, --3 17 G in their samples.…”
Section: Effects Of Quenchingcontrasting
confidence: 66%
“…It is worth pointing out here that Rubio eta1 [24], working with NaBr crystals doped with 130 ppm of Mn2+ and 8 ppm of Eu2+, also detect an EPR line with Lorentzian shape and having AH,,, = 300 I 30 G at room temperature. Moreover, they also indicate that such a line does not disappear even after heating the crystal at 800 K for several hours.…”
Section: Effects Of Quenchingmentioning
confidence: 61%
See 1 more Smart Citation
“…3b shows the schematic of the energy level system, which describes the energy transfer from Ce 3+ to Eu 2+ . According to previous results, 11,17,18 the electric dipole-dipole interaction usually predominates in the ET Ce→Eu mechanism, and the critical distance ͑R c ͒ of energy transfer from a sensitizer to an activator can be expressed by [17][18][19][20][21] R c 6 = 0.63 ϫ 10 28 4.8 ϫ 10 −16 P A E 4…”
Section: Resultsmentioning
confidence: 85%