Distributed Generation Systems 2017
DOI: 10.1016/b978-0-12-804208-3.00007-8
|View full text |Cite
|
Sign up to set email alerts
|

Energy Storage Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(15 citation statements)
references
References 25 publications
0
15
0
Order By: Relevance
“…In Steps (11) and (12), the BESS operation is adapted by evaluating the results of the Operational KPIs. If the assessment is positive for all Operational KPIs, then the BESS doesn't need to adapt, therefore no change is made in relation to the initial inputs and the day-ahead planning of operation with BESS is obtained in Step (13). If the BESS fails in Steps (7), (8) and (9), an easing of the restriction of the maximum equivalent cycles per day is implemented so that the energy storage system has more freedom of operation and, thus, may achieve improvements in the operation and the defined KPIs.…”
Section: Description Of the Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…In Steps (11) and (12), the BESS operation is adapted by evaluating the results of the Operational KPIs. If the assessment is positive for all Operational KPIs, then the BESS doesn't need to adapt, therefore no change is made in relation to the initial inputs and the day-ahead planning of operation with BESS is obtained in Step (13). If the BESS fails in Steps (7), (8) and (9), an easing of the restriction of the maximum equivalent cycles per day is implemented so that the energy storage system has more freedom of operation and, thus, may achieve improvements in the operation and the defined KPIs.…”
Section: Description Of the Methodologymentioning
confidence: 99%
“…This paradigm shift is the result of DG being connected in places where power injection was not planned, in particular, the fact that the infrastructure is designed for unidirectional power flows, from primary substations until consumers, which may not happen with a significant integration of distributed generation units [13].…”
Section: The Distribution Networkmentioning
confidence: 99%
“…A DC/DC converter, which allows to reach the point of maximum power using the MPPT control "perturb observe" [9]. A battery, whose objective is to store energy in order to compensate for the power level demanded by the loads during the absence of the operating condition 'solar irradiation' of the photovoltaic system [10]. A bidirectional DC/DC converter, allows the current to flow in two directions in order to manage the charge and discharge of the battery [11], [12].…”
Section: Presentation Of the Studied Systemmentioning
confidence: 99%
“…2) State-of-Charge ( SoC) : The SoC of a cell, expressed in (2), is defined as the percentage of currently available capacity ( Q c ) to its rated capacity ( Q n ) [55], and its value ranges between 0% up to 100%.…”
Section: Considered Key Factorsmentioning
confidence: 99%