42nd AIAA Aerospace Sciences Meeting and Exhibit 2004
DOI: 10.2514/6.2004-352
|View full text |Cite
|
Sign up to set email alerts
|

Energy Storage and Reactive Power Compensator in a Large Wind Farm

Abstract: The size of wind farm power systems is increasing, and so is the number of wind farms contributing to the power systems network. The size of wind turbines is also increasingfrom less than 1 MW a few years ago to the 2-to 3-MW machines being installed today and the 5-MW machines under development.The interaction of the wind farm, energy storage, reactive power compensation, and the power system network is being investigated. Because the loads and the wind farms' output fluctuate during the day, the use of energ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(14 citation statements)
references
References 2 publications
0
14
0
Order By: Relevance
“…Some of the BESS applications for wind farms involve a simple scheme to charge and discharge the BESS, such as storing excess power if the wind power output exceeds a threshold [11], [19], [20].…”
Section: Bess Control For Wind Farm Dispatchmentioning
confidence: 99%
See 1 more Smart Citation
“…Some of the BESS applications for wind farms involve a simple scheme to charge and discharge the BESS, such as storing excess power if the wind power output exceeds a threshold [11], [19], [20].…”
Section: Bess Control For Wind Farm Dispatchmentioning
confidence: 99%
“…These ramps should be limited in order to integrate the large amount of generation to the grid, minimize the high-cost ancillary service requirements, and reduce the impact on system reliability [7]. 3) Limiting wind farm power output: Large-scale wind power may cause congestion on the transmission lines that carry wind power (for example, when a large wind farm is integrated to a weak part of a system [1]), and hence, the power output of the wind farm may have to be curtailed to prevent congestion [11]. connected to the system at the point of common coupling and is charged/discharged through a power converter to smooth the net power injected to the system.…”
Section: Energy Storage For Wind Powermentioning
confidence: 99%
“…These elements can be controlled to operate in all four quadrants delivering/absorbing the real/reactive power [23] and limited up to their rated current. As a consequence, the capability curve of DSS units can be represented, in the P-Q, plane as shown in Fig.…”
Section: ) Sub-problemmentioning
confidence: 99%
“…Application of energy storage for wind farms in addressing wind farm intermittency is proposed in many papers. These papers include a simple scheme to charge and discharge the battery energy storage system (BESS), such as storing excess power if the wind power output exceeds a threshold [7]- [9].…”
Section: Introductionmentioning
confidence: 99%