Cochrane Database of Systematic Reviews 2009
DOI: 10.1002/14651858.cd007886
|View full text |Cite
|
Sign up to set email alerts
|

Energy source instruments for laparoscopic colectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 12 publications
0
16
0
Order By: Relevance
“…These devices expedite normally labor-intensive surgical procedures such as lobectomy, 1,2 nephrectomy, 3 gastric bypass, 4-6 splenectomy, 7,8 thyroidectomy, [9][10][11][12][13][14] hysterectomy, 15 and colectomy. [16][17][18][19] However, both electrosurgical and ultrasonic devices have limitations, including the potential for undesirable charring and unnecessarily large collateral thermal damage zones. [20][21][22] For example, more thermal energy is required to seal large blood vessels with such devices, and stray thermal energy escaping the seal area can lead to unintended lateral tissue thermal damage.…”
mentioning
confidence: 99%
“…These devices expedite normally labor-intensive surgical procedures such as lobectomy, 1,2 nephrectomy, 3 gastric bypass, 4-6 splenectomy, 7,8 thyroidectomy, [9][10][11][12][13][14] hysterectomy, 15 and colectomy. [16][17][18][19] However, both electrosurgical and ultrasonic devices have limitations, including the potential for undesirable charring and unnecessarily large collateral thermal damage zones. [20][21][22] For example, more thermal energy is required to seal large blood vessels with such devices, and stray thermal energy escaping the seal area can lead to unintended lateral tissue thermal damage.…”
mentioning
confidence: 99%
“…Current bipolar and ultrasonic laparoscopic instruments allow adequate surgical dissection without bleeding thanks to the satisfactory vessels sealing without injury to the surrounding tissues [5], and tend to diminish the surgical time because of their efficacy [6]. Among the available equipment in the market are the Harmonic scalpel™, Ligasure™ and Trissector™, with an average functioning time that varies from 3 to 11 seconds, with vessel sealing diameter from 3 to 7 mm, and shutting pressures to rupture of the blood vessels from 363 to 536mmHg [7].…”
Section: Discussionmentioning
confidence: 99%
“…A review of the literature did not reveal one energy type or device to be superior for laparoscopic colectomy or associated with a lower rate of inadvertent or missed organ injury. 119 Blunt dissection is a useful adjunct to release thin adhesions or to create more space between organs and the abdominal wall for energy device use. The general principle of working from known to unknown structures in open surgery also applies to minimally invasive adhesiolysis to maximize safety during dissection.…”
Section: Avoiding Organ Injury: Surgical Techniquementioning
confidence: 99%