2015
DOI: 10.7763/jocet.2016.v4.257
|View full text |Cite
|
Sign up to set email alerts
|

Energy, Exergy and Anergy Analysis of a Solar Desiccant Cooling System

Abstract: Abstract-Some alternative and cost effective approaches are needed for space cooling of buildings in order to resolve environmental and economic issues. Desiccant cooling is one of the alternative to conventional air conditioning systems which can solve many problems related to air conditioning. In this paper a method is developed for energy, exergy and anergy analysis of the desiccant cooling system operating on ventilation cycle. Both exergy and energy analysis are usually applied in parallel in order to fin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…COP for a desiccant cooling system varies between 0.25 and 0.8 and L/G ratio is found effective parameter to consider for LDCS. As per Rafique et al (2016) Desiccant cooling is one of the alternatives to conventional air conditioning systems which can solve many problems related to air conditioning. Energy and exergy analysis were done using a theoretical model of the desiccant cooling system and conveyed that rotary desiccant wheel and solar collector are the main reason of exergy destruction because of the irreversibility available.…”
Section: Introductionmentioning
confidence: 99%
“…COP for a desiccant cooling system varies between 0.25 and 0.8 and L/G ratio is found effective parameter to consider for LDCS. As per Rafique et al (2016) Desiccant cooling is one of the alternatives to conventional air conditioning systems which can solve many problems related to air conditioning. Energy and exergy analysis were done using a theoretical model of the desiccant cooling system and conveyed that rotary desiccant wheel and solar collector are the main reason of exergy destruction because of the irreversibility available.…”
Section: Introductionmentioning
confidence: 99%
“…Among these technologies, desiccant cooling is the main focus of many researchers for past few years. Several studies describe the basic operation of desiccant cooling system . It has been proved that desiccant system has several advantages over vapor compression air conditioning systems .…”
Section: Introductionmentioning
confidence: 99%
“…Several studies describe the basic operation of desiccant cooling system. System with rotary dehumidifier commonly known as desiccant wheel are most widely used and studied [2,3]. Although, absorption chillers are used in European market as solar cooling systems but trend is now changing towards desiccant cooling technology.…”
Section: Introductionmentioning