2016
DOI: 10.1016/j.enconman.2015.06.080
|View full text |Cite
|
Sign up to set email alerts
|

Energy–exergy analysis and economic investigation of a cogeneration and trigeneration ORC–VCC hybrid system utilizing biomass fuel and solar power

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
65
0
7

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 241 publications
(80 citation statements)
references
References 24 publications
0
65
0
7
Order By: Relevance
“…There is a need to change the location of CDCs to reduce cooling costs and it can be done through placing the CDCs to that area which has availability of free cooling resources. Due to consumption of large amount of energy, CDCs are acting as a heat generator [130] [131]. The vapor-absorption based cooling systems of CDCs can use waste heat, then it takes away the heat while evaporating.…”
Section: Waste Heat Utilizationmentioning
confidence: 99%
“…There is a need to change the location of CDCs to reduce cooling costs and it can be done through placing the CDCs to that area which has availability of free cooling resources. Due to consumption of large amount of energy, CDCs are acting as a heat generator [130] [131]. The vapor-absorption based cooling systems of CDCs can use waste heat, then it takes away the heat while evaporating.…”
Section: Waste Heat Utilizationmentioning
confidence: 99%
“…The utilization of hybrid systems, which use both biomass and solar energy, has been developed in recent years. Various analysis including energy, exergy and economic were applied in cogeneration and trigeneration hybrid system . A novel electricity heating cogeneration system was studied based on thermodynamic and an analysis was performed for both specific and variable conditions .…”
Section: Three‐e Analyses Of Power Plantsmentioning
confidence: 99%
“…Various analysis including energy, exergy and economic were applied in cogeneration and trigeneration hybrid system. 193 A novel electricity heating cogeneration system was studied based on [160] -○ • ○ An integrated organic Rankine cycle is assessed based on exergy concept, and it was observed that the heating-cogeneration and trigeneration cases were less sensitive to the considered pressure and temperature changes in comparison with the electrical power and cooling-cogeneration cases.…”
mentioning
confidence: 99%
“…There are some other studies are done on ORC and VCC with separate cooling and power cycles with different working fluids to find desirable results [13,14,15,16,17]. Some other studies is also done using single working fluid for separate cooling cycles of ORC and VCC and found desirable combination for their system [18,19,20,21].…”
Section: Introductionmentioning
confidence: 99%