2020
DOI: 10.1016/j.enconman.2020.112929
|View full text |Cite
|
Sign up to set email alerts
|

Energy, economic and environmental evaluation of a novel combined cooling and power system characterized by temperature and humidity independent control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 41 publications
1
3
0
Order By: Relevance
“…The minimum production cost was 53.25$/MWh (14.73$/GJ). This production cost is similar to the one reported by Li et al, 86 but this cycle has the disadvantage of requiring much higher operating temperatures. The exergy analysis showed that the highest ExD occurred in the turbine of the ORC, comprising 41.26% of the total ExD.…”
Section: Hybrid Systems Integrated By Three Cyclessupporting
confidence: 85%
See 2 more Smart Citations
“…The minimum production cost was 53.25$/MWh (14.73$/GJ). This production cost is similar to the one reported by Li et al, 86 but this cycle has the disadvantage of requiring much higher operating temperatures. The exergy analysis showed that the highest ExD occurred in the turbine of the ORC, comprising 41.26% of the total ExD.…”
Section: Hybrid Systems Integrated By Three Cyclessupporting
confidence: 85%
“…From the exergy analysis, it was found that the highest ExD occurred in the condenser, turbine and regenerator, comprising 33.24%, 15.99%, and 14.72% of the total ExD, respectively. Li et al 86 reported the thermo‐economic study of a system integrated by a geothermal cycle, an ORC, and a compression refrigeration system using R1234yf, R134a, R600a, R600, R123, R601. The system was proposed to produce power and cooling.…”
Section: Hybrid Systems Integrated By Three Cyclesmentioning
confidence: 99%
See 1 more Smart Citation
“…The system schematic diagram of CRFH is shown in Fig.7 (a) , which consists of an ASHP loop and a hot water loop. R134a is used as the working fluid in the ASHP cycle due to its efficient performance and environmental-friendly [50] . A heat exchanger is used to connect the ASHP loop and a hot water loop, allowing the transfer of heat from the heat pump to the tank.…”
Section: Methodsmentioning
confidence: 99%
“…For specific applications, an HDR cogeneration system that combines wind and PV energy as power sources to meet the cold, heat, and electricity demands of an independent micro-energy grid was proposed in [23]. In [24], a new type of combined cooling and power supply system was proposed in order to meet the energy demand of buildings, which can meet the seasonal cooling and power demand of buildings and maximize the utilization of hot dry rock resources.…”
Section: Introductionmentioning