Energy-dispersive Laue diffraction by means of a frame-store pnCCD

Abstract: A frame‐store pn‐junction CCD detector was applied to the energy‐dispersive X‐ray Laue diffraction study of a γ‐LiAlO2 crystal with white synchrotron radiation. Exploiting the simultaneous spatial and energy resolution of the detector the crystallographic unit cell of γ‐LiAlO2 could be determined without any a priori information about the sample. The potential for application in X‐ray structure analysis is tested by comparing experimental structure factors taken under a single exposure with those calculated fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
37
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(37 citation statements)
references
References 8 publications
0
37
0
Order By: Relevance
“…Every observed peak is an integer multiple of the base energy (see section 3.3). 4. Spot spectrum and background spectrum are extracted.…”
Section: Base Algorithmmentioning
confidence: 99%
See 1 more Smart Citation
“…Every observed peak is an integer multiple of the base energy (see section 3.3). 4. Spot spectrum and background spectrum are extracted.…”
Section: Base Algorithmmentioning
confidence: 99%
“…The possibility of unit-cell calculation without additional information and the need for sample rotation is a clear advantage of the Laue method compared to monochromatic applications. Moreover, absolute intensity determination allows to extract kinematical structure-factor moduli of individual position-and energy-resolved Bragg peaks of the crystal from the pnCCD-generated data sets with adequate accuracy [4]. Recently, energydispersive Laue diffraction with a pnCCD was considered in the ultra-hard X-ray regime between 40 keV and 140 keV providing a sufficiently large Laue spot density to investigate inorganic crystals in one single measurement [5].…”
Section: Introductionmentioning
confidence: 99%
“…Three methods were developed for that purpose: switching from polychromatic mode to tunable-energy monochromatic beam mode [37], using 1D or 2D energy dispersive detectors [31,38] and a crystal filter [39] while remaining in the polychromatic mode. In this study, an energy dispersive point detector was used (see Fig.…”
Section: Materials Preparation and Samplesmentioning
confidence: 99%
“…The use of position sensitive detectors with capability of energy resolution measurements (e.g. hybrid pixel Pilatus detector [2], frame store pnCCD [3] etc.) allows overcoming such problems as the energy-dispersive analysis of Bragg peaks enables a unique determination of the lattice and resolution of higher harmonics without any a priory information [3].…”
mentioning
confidence: 99%
“…hybrid pixel Pilatus detector [2], frame store pnCCD [3] etc.) allows overcoming such problems as the energy-dispersive analysis of Bragg peaks enables a unique determination of the lattice and resolution of higher harmonics without any a priory information [3]. Energy-dispersive Laue diffraction (EDLD) experiments are usually done at synchrotron sources with high intense x-ray irradiation.…”
mentioning