2019
DOI: 10.1016/j.applthermaleng.2019.113853
|View full text |Cite
|
Sign up to set email alerts
|

Energy and techno-economic assessment of the effect of the coupling between an air source heat pump and the storage tank for sanitary hot water production

Abstract: Energy and techno-economic assessment of the effect of the coupling between an air source heat pump and the storage tank for sanitary hot water production.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 13 publications
0
3
0
1
Order By: Relevance
“…This system adopts a variable-volume water level tank model, which facilitates the simulation of the direct heat water production mode and circulation heat preservation mode of the air-source heat pump hot water unit controlled by changes in the water level of the tank. The mathematical model of the variable-volume water tank can be simplified to a completely mixed variable-mass water, and the calculation method for describing the changes in the mass and internal energy of the water in the tank is as follows [25][26][27]:…”
Section: Mathematical Model Establishment (1) Mathematical Model Of T...mentioning
confidence: 99%
“…This system adopts a variable-volume water level tank model, which facilitates the simulation of the direct heat water production mode and circulation heat preservation mode of the air-source heat pump hot water unit controlled by changes in the water level of the tank. The mathematical model of the variable-volume water tank can be simplified to a completely mixed variable-mass water, and the calculation method for describing the changes in the mass and internal energy of the water in the tank is as follows [25][26][27]:…”
Section: Mathematical Model Establishment (1) Mathematical Model Of T...mentioning
confidence: 99%
“…Regarding the connection between the tank and the SHP, a direct connection has been considered in this study. The effects of an indirect connection could also be studied as it has been done in [36].…”
Section: Tes Tanksmentioning
confidence: 99%
“…Sin embargo, los criterios de diseño que aborden el problema del reto energético desde el origen suponen el enclave científico que debe tomarse en cuenta para mejorar la eficiencia de las instalaciones (Rankin, R. & Rousseau, P.G., 2006). Así pues, ahorrar agua permite de forma proporcional ahorrar la energía utilizada para su calentamiento, aportando beneficios, ya no tanto económicos y muy importantes, sino ecológicos, por evitar la combustión, reduciendo la emisión de gases contaminantes y el efecto invernadero asociado, derivados todos ellos del consumo y obtención de otras energías, así como de su trasformación y/o combustión (Masip, X. et al, 2019). En la Tabla 1 se ha realizado una comparación entre algunos de los sistemas más empleados en la actualidad, y cuya representación se muestra en la Figura 4.…”
Section: Estado Del Conocimiento Actualunclassified