2023
DOI: 10.1016/j.est.2023.106693
|View full text |Cite
|
Sign up to set email alerts
|

Energy and exergy analysis of an unglazed transpired collector connected to a dryer with a porous plate and phase change material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 57 publications
0
2
0
Order By: Relevance
“…Initially, the following considerations are made: the electrical power of the fan (𝑃 ̇𝑒𝑙𝑒𝑐 ) is 0.04 kW [39]; the average unit cost of electricity (𝑐 𝑒𝑙𝑒𝑐 ) was obtained from XM (electricity market managers) with a value equivalent to 0.103 USD/kWh for the year 2022 in Colombia; the average heat transfer in the investigated collector (𝑄 Μ‡π‘π‘œπ‘™π‘™,π‘Žπ‘–π‘Ÿ ) is 471.3672 W; the annual operation time of the equipment 𝑑 π‘œπ‘¦ is equivalent to 2880 h/year; and the economic life (𝑑 𝑒𝑙 of this equipment according to the market is 20 years [10], [13]. With the estimates made above, the levelized process heating cost (LCOH), which indicates the cost of producing one kWh of thermal energy, is calculated according to equation (22).…”
Section: Economic Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Initially, the following considerations are made: the electrical power of the fan (𝑃 ̇𝑒𝑙𝑒𝑐 ) is 0.04 kW [39]; the average unit cost of electricity (𝑐 𝑒𝑙𝑒𝑐 ) was obtained from XM (electricity market managers) with a value equivalent to 0.103 USD/kWh for the year 2022 in Colombia; the average heat transfer in the investigated collector (𝑄 Μ‡π‘π‘œπ‘™π‘™,π‘Žπ‘–π‘Ÿ ) is 471.3672 W; the annual operation time of the equipment 𝑑 π‘œπ‘¦ is equivalent to 2880 h/year; and the economic life (𝑑 𝑒𝑙 of this equipment according to the market is 20 years [10], [13]. With the estimates made above, the levelized process heating cost (LCOH), which indicates the cost of producing one kWh of thermal energy, is calculated according to equation (22).…”
Section: Economic Analysismentioning
confidence: 99%
“…The most used way to store latent heat in flat plate solar collectors is the application of phase change material (PCM), which allows for increased thermal efficiency between the absorber plate and the working fluid. Because solar radiation and ambient temperature vary at every instant, the PCM acts as thermal storage in the system for a prolonged period when the energy source is no longer available [21], [22]. Table 1 presents experimental investigations on solar collectors using thermal storage to increase the temperature of the fluid in the equipment.…”
Section: Introductionmentioning
confidence: 99%