2001
DOI: 10.1088/0953-2048/14/4/301
|View full text |Cite
|
Sign up to set email alerts
|

Energy and critical current considerations of Bi(2223)/Ag coils for micro-superconducting magnetic energy storage: influence of operating temperature and winding geometry within the same overall tape length

Abstract: A detailed theoretical qualitative, as well as quantitative, analysis of the influence of the dimensions of Bi(2223)/Ag based cylindrical magnets on the energy stored in the magnet's winding was performed for various operating temperatures. The results achieved can be used to consider the potential suitability of the high-temperature superconductivity magnets for the purposes of micro-superconducting magnetic energy storage applications. A mathematical model which enables one to calculate the values of basic p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2002
2002
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 33 publications
(37 reference statements)
0
12
0
Order By: Relevance
“…This is because the magnetic field is the largest there and the anisotropy of the tape is not very large (figure 2). This is in contrast to coils made of Bi2223 tapes, where the limiting turn is at the average radius on the top and bottom ends [51]. The reason is that Bi2223 tapes are highly anisotropic.…”
Section: Critical Current Of the Coilsmentioning
confidence: 89%
“…This is because the magnetic field is the largest there and the anisotropy of the tape is not very large (figure 2). This is in contrast to coils made of Bi2223 tapes, where the limiting turn is at the average radius on the top and bottom ends [51]. The reason is that Bi2223 tapes are highly anisotropic.…”
Section: Critical Current Of the Coilsmentioning
confidence: 89%
“…STEP6: STEP6 has two kinds of procedures for each section in this paper. , which is the electric field criterion of the minimum critical current I cmin [19,20]. We finally obtain the current, I, versus voltage, V , characteristics and the critical current, I cmin , of the HTS coil.…”
Section: Step4mentioning
confidence: 99%
“…The experimental data (Table 1) are close to calculated stored energy values. We received with coil made of 600 m wire (doubled wire was used) the stored energy that can be received without core with 5 km of HTS wire [7].…”
Section: Example Of Smesmentioning
confidence: 99%
“…The major elements of these SMES's are Nb-Ti coils immersed in liquid helium bath. But HT-SMES's presently pass through the first stage of research and development [2][3][4][5][6][7]. This process already encountered several difficulties related to their electromagnetic and thermal properties.…”
Section: Introductionmentioning
confidence: 99%