2022
DOI: 10.3390/en15228460
|View full text |Cite
|
Sign up to set email alerts
|

Energy Analysis and Cost-Effective Design Solutions for a Dual-Source Heat Pump System in Representative Climates in Europe

Abstract: Ground-source heat pumps are an efficient technology for heating and cooling in buildings. However, the main limitation of their widespread application is the borehole heat exchanger’s (BHE) high investment cost. Hybridizing GSHP systems may overcome this limitation. This research work analyzes the long-term energy performance of a dual-source heat pump (DSHP) system, which uses the air or the ground as external heat/sink sources, in three representative European climates. First, a BHE cost-effective design so… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…The first modeling type [ 12 ] is based on the detailed knowledge of the process and its physics, (i.e., energy balance, thermodynamic equations, laws of conservation, etc.) and the thermal model is mathematically detailed many times by employing dedicated simulation software such as Transys [ 13 , 14 ], EnergyPlus [ 15 , 16 ], COMSOL [ 17 , 18 ], or Modelica [ 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…The first modeling type [ 12 ] is based on the detailed knowledge of the process and its physics, (i.e., energy balance, thermodynamic equations, laws of conservation, etc.) and the thermal model is mathematically detailed many times by employing dedicated simulation software such as Transys [ 13 , 14 ], EnergyPlus [ 15 , 16 ], COMSOL [ 17 , 18 ], or Modelica [ 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…Thе only significant drawback of thе GSHP is thе initial capital invеstmеnts, which arе 2-3 timеs highеr for GSHP. At thе samе timе, study [18] shows thе bеnеfits of combining ASHP and GSHP in a dual-sourcе hеat pump systеm with еvaluation for thrее rеprеsеntativе climatеs in Еuropе. Thе sourcе control optimization mеthod rеsults in only slight еfficiеncy gains (<0.35 %) but with a strongеr еffеct on thе ground/air usе ratio (up to 25 % usе of air in cold climatеs), rеducing thе thеrmal imbalancе of thе ground and lеading to a consеquеnt BHЕ sizе lеngth and cost rеduction.…”
Section: Introductionmentioning