2019
DOI: 10.1016/j.energy.2018.11.081
|View full text |Cite
|
Sign up to set email alerts
|

Energetic and exergetic investigation of a novel refrigeration system utilizing ejector integrated subcooling using different refrigerants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…Li et al [18] analytically studied a solarbased ejector-cascade heat pump (coupling a R134a, R1234yf, R141b ejector cycle with a R1234yf vapor compression system); Khaliq et al [19] analytically studied the integration of a solar-based organic rankine cycle (R141b, R600a, R290, R717, R143a) with a NH 3 -LiNO 3 ejector-absorption cycle. Yilmaz et al [20] proposed a screening of refrigerants (R134a, R1234yf, R245fa, R290, R32, R717, R600a) to assess the performance of a novel ERS with a subcooling. Despite above-mentioned references proposed just a simple view regarding ongoing activities, it is clear that the use of low-GWP refrigerants in ejector systems is a matter of intense discussion.…”
mentioning
confidence: 99%
“…Li et al [18] analytically studied a solarbased ejector-cascade heat pump (coupling a R134a, R1234yf, R141b ejector cycle with a R1234yf vapor compression system); Khaliq et al [19] analytically studied the integration of a solar-based organic rankine cycle (R141b, R600a, R290, R717, R143a) with a NH 3 -LiNO 3 ejector-absorption cycle. Yilmaz et al [20] proposed a screening of refrigerants (R134a, R1234yf, R245fa, R290, R32, R717, R600a) to assess the performance of a novel ERS with a subcooling. Despite above-mentioned references proposed just a simple view regarding ongoing activities, it is clear that the use of low-GWP refrigerants in ejector systems is a matter of intense discussion.…”
mentioning
confidence: 99%
“… For the cooling mode of the ORC-VCC system, the difference between the condensation temperature and the ambient air temperature was considered to be 10 [22], [23]. This value is practically recommended for obtaining appropriate cost of heat exchanger [24].…”
Section: Fig1 Schematic Views Of Heating and Cooling Modes Of Orc-vccmentioning
confidence: 99%
“…Among the refrigerants examined ref. [11], R290 was found to have global warming potential (GWP) and zero emission. R290 is regarded as an environmentally friendly, economical, and practical refrigerant with suitable cooling performance [12,13].…”
Section: Introductionmentioning
confidence: 99%