2007
DOI: 10.1016/j.jvir.2007.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Endovascular Repair of a Traumatic Aortic Transection in a Pediatric Patient

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The endograft device was transferred to the new delivery system via previously described techniques and delivered under fluoroscopic guidance. 11,12 Poststent placement DSA evaluation confirmed expectations that two devices would be required. The second 20 Â 55 mm iliac limb extension device was transferred to the sheath, delivered to the thoracic aorta via the sheath, and deployed under fluoroscopic imaging.…”
Section: Case 2: Decision Process and Techniquesmentioning
confidence: 62%
“…The endograft device was transferred to the new delivery system via previously described techniques and delivered under fluoroscopic guidance. 11,12 Poststent placement DSA evaluation confirmed expectations that two devices would be required. The second 20 Â 55 mm iliac limb extension device was transferred to the sheath, delivered to the thoracic aorta via the sheath, and deployed under fluoroscopic imaging.…”
Section: Case 2: Decision Process and Techniquesmentioning
confidence: 62%
“…5,7,8 Naturally, this approach has also been applied to the pediatric population. 9,10 In our patient, due to her closed head injury, open surgical repair with anticoagulation was not a viable option. The patient was kept in the ICU with tight systolic arterial blood pressure control.…”
Section: Discussionmentioning
confidence: 86%
“…10 In one series, 6% of the patients admitted for TAI were patients younger than 16 years of age. 3 Three patients underwent endovascular repair with aortas measuring 13 to 16 mm in diameter, similar to our patient.…”
Section: Discussionmentioning
confidence: 97%
“…A thorough understanding of available devices is required to ensure proper device selection and deployment. A variety of available ancillary devices can be utilized successfully to treat various aortic trauma when standard aortic devices do not accommodate patient anatomy 10,11 as well as other vascular injuries when standard devices are not applicable.…”
Section: Discussionmentioning
confidence: 99%