2019
DOI: 10.5758/vsi.2019.35.2.70
|View full text |Cite
|
Sign up to set email alerts
|

Endovascular Intervention with a Mobile C-Arm in the Operating Room

Abstract: Mobile C-arm fluoroscopic X-ray systems are used for various diagnostic imaging and minimally invasive endovascular procedures. One of the greatest advantages of a mobile C-arm is its ability to move around the patient. The purpose of this study was to address the optimal setting of the mobile C-arm and the operating table, as well as the proper position of the operator and assistants for each procedure. In addition, methods to minimize radiation exposure to the operator and medical staff are described. Both t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Dentro de uma sala de cirurgia, esses equipamentos estão presentes em diversos procedimentos dentro da Urologia, Cardiologia, Neurologia e principalmente da Ortopedia. A fluoroscopia mostra-se muito útil no Bloco Operatório e nas Salas de Intervenção, pois é necessário existir uma versatilidade de funcionalidades de aquisição de imagens [9].…”
Section: Discussão E Resultadosunclassified
“…Dentro de uma sala de cirurgia, esses equipamentos estão presentes em diversos procedimentos dentro da Urologia, Cardiologia, Neurologia e principalmente da Ortopedia. A fluoroscopia mostra-se muito útil no Bloco Operatório e nas Salas de Intervenção, pois é necessário existir uma versatilidade de funcionalidades de aquisição de imagens [9].…”
Section: Discussão E Resultadosunclassified
“…Based on previous fluoroscopy studies, a sample-size calculation before the initiation of the study identified a requirement of 40 patients per group to measure a 20% difference in mean imaging quality with a power of 0.80 Given the expectation of a 5% difference, we exceeded the calculated sample-size calculation required to account for incomplete or missing data and projected patient withdrawal from study protocol 15 16 17 18 19 20 21 22 23 24 25 26 27 28 .…”
Section: Methodsmentioning
confidence: 99%
“…Additionally, newer fluoroscopy equipment provides options to limit radiation delivery in the form of lower radiation dose and frame rate or time-limited "pulsed" settings. Pulsed settings have been utilized and have demonstrated successful reduction in RE in many fields including orthopedics, neurosurgery, anesthesia, interventional radiology, vascular surgery, urology, and cardiology [15][16][17][18][19][20][21][22][23][24][25][26][27][28]. The angle or positioning of the C-arm has been shown to impact the level of radiation to the surgeon, and lung and colon cancers appear to be of greatest risk to surgeon [29].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation