2017
DOI: 10.1177/2050640616680972
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic ultrasound‐guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta‐analysis

Abstract: Our meta-analysis reveals non-superiority of 25 Gauge over 22 Gauge; hence no definitive recommendations over the use of one particular device can be made.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
48
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 61 publications
(52 citation statements)
references
References 32 publications
3
48
0
1
Order By: Relevance
“…The great strength of FNA is its excellent specificity (around 100% in nearly all studies), while there are still conflicting results regarding its sensitivity (which ranges from 85-93% in most trials) and sample adequacy [ 1 , 2 ]. Many technical aspects, such as needle caliber or the availability of ROSE [ 1 - 4 ], and several devices have been investigated and developed in order to improve the diagnostic performance of EUS-FNA, but none of them was proven determinant as regards reaching an optimal diagnostic accuracy.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The great strength of FNA is its excellent specificity (around 100% in nearly all studies), while there are still conflicting results regarding its sensitivity (which ranges from 85-93% in most trials) and sample adequacy [ 1 , 2 ]. Many technical aspects, such as needle caliber or the availability of ROSE [ 1 - 4 ], and several devices have been investigated and developed in order to improve the diagnostic performance of EUS-FNA, but none of them was proven determinant as regards reaching an optimal diagnostic accuracy.…”
Section: Discussionmentioning
confidence: 99%
“…EUS-guided FNA, although showing an excellent specificity up to 100%, has a variable sensitivity (ranging from 85% to over 93%) that depends on several factors, such as the availability of rapid on-site tissue evaluation (ROSE) by a cytopathologist, or the needle caliber [ 1 - 4 ]. This variability may lead to false-negative results, particularly in cases of pancreatic cancer occurring in patients with chronic pancreatitis.…”
Section: Introductionmentioning
confidence: 99%
“…Five metaanalyses have compared the diagnostic performance of these needles; 2 suggested that 25G needles have better diagnostic sensitivity, 4,5 and 3 observed no such difference. [6][7][8] Therefore, it remains unclear whether the diagnostic performance of both 22G and 25G needles are similar or if one may be more advantageous.…”
mentioning
confidence: 99%
“…[ 172 173 174 175 ] One study has shown a higher accuracy for the 25-G needle;[ 169 ] the others have shown no significant difference in diagnostic accuracy. Studies comparing FNA with 25-G and 22-G needles were also subjected to four meta-analyses[ 176 177 178 179 ] that provided conflicting results. The recent meta-analysis by Facciorusso et al .,[ 176 ] comprising only randomized clinical trials, did not show significant differences between the needles in terms of sensitivity and specificity for pancreatic malignancy.…”
Section: Needle Size: Small Vs Largementioning
confidence: 99%
“…Studies comparing FNA with 25-G and 22-G needles were also subjected to four meta-analyses[ 176 177 178 179 ] that provided conflicting results. The recent meta-analysis by Facciorusso et al .,[ 176 ] comprising only randomized clinical trials, did not show significant differences between the needles in terms of sensitivity and specificity for pancreatic malignancy. On the other hand, Xu et al .…”
Section: Needle Size: Small Vs Largementioning
confidence: 99%