2009
DOI: 10.1007/s00464-009-0560-x
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic submucosal dissection with a combination of small-caliber-tip transparent hood and flex knife is a safe and effective treatment for superficial esophageal neoplasias

Abstract: ESD with a combination of small-caliber-tip transparent hood and flex knife is a safe endoscopic treatment for superficial esophageal neoplasias and enables large en bloc resection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
24
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
3
3
2

Relationship

2
6

Authors

Journals

citations
Cited by 38 publications
(26 citation statements)
references
References 32 publications
2
24
0
Order By: Relevance
“…Recently, ESD has been applied to esophageal neoplasias because it provides a higher en bloc resection rate and is less invasive than surgical resection [4][5][6][7][8][9].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, ESD has been applied to esophageal neoplasias because it provides a higher en bloc resection rate and is less invasive than surgical resection [4][5][6][7][8][9].…”
Section: Discussionmentioning
confidence: 99%
“…After additional injection was made to lift the lesion, the smallcaliber-tip transparent hood attached to the endoscope tip, was inserted into the thickened submucosal layer to maintain a satisfactory view and make this layer more stretched so that the submucosal layer could be dissected safely (Figs. 7,8,9). During dissecting of the submucosal layer, the flex knife was set to approximately 1 mm in length and the electrosurgical generator output was set at 20 W in swift coagulation mode, effect 3.…”
Section: Esd Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, we applied a combination of flex knife and small-caliber-tip transparent hood to colorectal ESD such as esophageal ESD [29]. The flex knife has special features [2].…”
Section: Discussionmentioning
confidence: 99%
“…Marking dots for the incision were made 3-5 mm outside of lesion margins with a flex knife [19][20][21] (Flex Knife TM , KD-630L; Olympus Medical Systems, Tokyo, Japan) ( Figure 1A and B). A solution of 0.4%-0.5% sodium hyaluronate was injected into the submucosal layer beneath the lesion, and circumferential incisions were made around the marking dots with a flex knife.…”
Section: Re-esd Methodsmentioning
confidence: 99%