2007
DOI: 10.1007/s00393-007-0193-1
|View full text |Cite
|
Sign up to set email alerts
|

Endoprothetik des Fingergrundgelenks

Abstract: Only a few of the large number of implants developed during the last decades for replacement of the metacarpophalangeal (MCP) joint have proven to be reliable. The rates of loosening and mechanical failure of almost all types of constrained prostheses are so high that their use cannot be recommended at present. For more than 40 years silicone arthroplasty according to Swanson has been regarded as the gold standard in the prosthetic replacement of the MCP joint. In long-term studies this device provided good pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0
2

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 45 publications
1
3
0
2
Order By: Relevance
“…Despite distinctive radiographic loosening and subsidences of all 4 implants, 3 implants are well functioning with a satisfactory outcome in a RA patient with high-demand activities of daily living. This feature (discrepancy between radiographic findings and good subjective results and without necessity of surgical revision in the absence of clinical symptoms) is known from the use of the silicone rubber and pyrocarbon implants [4,6,8,16,17,31]. However, due to the absence of larger case series with long-term follow-up's in the literature, it cannot be concluded that the RM prosthesis is really a reliable option for treatment of RA affecting the MCPJs.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite distinctive radiographic loosening and subsidences of all 4 implants, 3 implants are well functioning with a satisfactory outcome in a RA patient with high-demand activities of daily living. This feature (discrepancy between radiographic findings and good subjective results and without necessity of surgical revision in the absence of clinical symptoms) is known from the use of the silicone rubber and pyrocarbon implants [4,6,8,16,17,31]. However, due to the absence of larger case series with long-term follow-up's in the literature, it cannot be concluded that the RM prosthesis is really a reliable option for treatment of RA affecting the MCPJs.…”
Section: Resultsmentioning
confidence: 99%
“…The constrained MCPJ arthroplasty was designed to decrease the risk of recurrence of palmar (sub) luxation and ulnar deviation postoperatively due to the inherent lack of ligamentous support that was found in up to 31% of patients with RA who underwent a silicone rubber implant arthroplasty [5]. However, the rates of loosening and mechanical failure of almost all types of constrained prostheses are so high that their use cannot be recommended at present [6]; and the role of the piston effect, primarily known from the silicone rubber implant that increases the range of motion of the proximal phalanx , for breakage of prosthesis in cases of loosened nonsilicone uncemented MCPJ implants such as in unconstrained resurfacing pyrocarbon arthroplasty [8,9] or in constrained arthroplasty such as in our following case presentation, is not clearly understood currently. The second generation of the constrained and uncemented MCPJ RM prosthesis (Mathys, Bettlach, Switzerland) is one type that is in use [10].…”
Section: Introductionmentioning
confidence: 99%
“…Протез NeuFlex -более современная модель на рынке, созданная в 1998 г. компанией «DePuy» [33][34][35][36][37]. Главной особенностью дизайна стал 30-градусный нейтральный угол, направленный на воссоздание естественной «отдыхающей» позиции руки, что, предположительно, устраняет стрессвоздействие на имплантат, особенно на узловое соединение.…”
Section: силиконовые спейсерыunclassified
“…Примером может служить модель Ascension, показавшая достаточную стабильность, вызвавшая высокую удовлетворенность пациентов, увеличившая средний объем движений и выживаемость. Однако модель была запрещена по двум причинам: 1) из-за низкой костной фиксации и последующей суб люксации; 2) из-за неудовлетворительных рентгенологических показателей (ободок просветления на границе имплантат-кость) [33,39].…”
Section: третье поколение протезовunclassified
“…10,11 Swanson implants are one of most silicone implants frequently used for joint reconstruction; specifically, for the metacarpophalangeal and metatarsophalangeal joints. 1,6,7,[12][13][14][15][16][17][18][19] Some other implants as Tornier have been created with an axial offset hinge design, which reduces stress on the prosthesis and improves biomechanical function, a characteristic that is not considered in Swanson implants. Moreover, joint flexion for Swanson implant has been measured after implantation finding a mean active and passive arc of motions of 36.80°(SD 19.13) and 46.82° (SD 17.19), respectively.…”
Section: Introductionmentioning
confidence: 99%