1999
DOI: 10.1016/s0967-2109(99)00018-6
|View full text |Cite
|
Sign up to set email alerts
|

Endoluminal repair of infrarenal abdominal aortic aneurysms using a modular stent-graft: one-year clinical results from a European multicentre trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2000
2000
2007
2007

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 11 publications
0
4
0
1
Order By: Relevance
“…6 To increase the number of eligible patients, modular bifurcated endovascular prostheses are being evaluated in clinical trials. 4,5 Basic anatomical requirements for application of bifurcated prostheses include adequate length and diameter, without excessive angulation, of the proximal aortic neck and iliac arteries, respectively. 3 Moreover, extensive mural thrombus and calcification in the proximal endograft attachment zone may force patient exclusion.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…6 To increase the number of eligible patients, modular bifurcated endovascular prostheses are being evaluated in clinical trials. 4,5 Basic anatomical requirements for application of bifurcated prostheses include adequate length and diameter, without excessive angulation, of the proximal aortic neck and iliac arteries, respectively. 3 Moreover, extensive mural thrombus and calcification in the proximal endograft attachment zone may force patient exclusion.…”
Section: Discussionmentioning
confidence: 99%
“…Because the aneurysm anatomy met the inclusion criteria for our protocol, 4 the patient was accepted for endovascular treatment with a self-expanding modular bifurcated stent-graft (Medtronic AneuRx, Inc., Cupertino, CA, USA). 4,5 At the time of inter- vention, intravascular ultrasound was used to obtain definitive aortic and iliac dimensions. Under fluoroscopic guidance, a 28-mm-diameter bifurcated stent-graft segment with a 16-mm iliac limb was inserted and deployed uneventfully in the aorta and right common iliac artery, respectively.…”
Section: Case Reportmentioning
confidence: 99%
See 1 more Smart Citation
“…By the early 1990s, elective aneurysm repair was regularly carried out with mortality rates less than 5% [2]. The pace of progress accelerated even further with the advent of endoluminal approaches to aneurysm repair, beginning in 1991 [3]., The minimal morbidity associated with these techniques has dramatically changed our management approach to aortic aneurysm disease, and endoluminal repair of AAAs may already be considered commonplace [4][5][6][7][8][9]. It is therefore timely to consider how 0';1r approach to AAAs is likely to change even further In the near future.…”
Section: Introductionmentioning
confidence: 99%
“…Similarmente como o que ocorre na cirurgia convencional, complicações neurológicas após o tratamento endovascular de AAA é uma situação rara. A incidência na literatura varia de 0 -1% (BLUM, 1998;MACHAN, 1998;NOLTHENIUS, 1999;ZARINS, 1999;BUTH, 2000). Da mesma forma com que ocorre na cirurgia convencional no tratamento de AAA, o implante de endoprótese também, usualmente, preserva pelo menos uma artéria ilíaca interna.…”
Section: -Resultados Histopatológicosunclassified