2022
DOI: 10.1007/s10151-022-02642-9
|View full text |Cite
|
Sign up to set email alerts
|

Endocuff-assisted versus standard colonoscopy for improving adenoma detection rate: meta-analysis of randomized controlled trials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 42 publications
0
2
0
Order By: Relevance
“…water-assisted colonoscopy, right-sided retroflection, double right-side examination, and patient position change during scope withdrawal) have improved ADR. [70][71][72] Additionally, advanced technology aimed at improving ADR can be divided into: (i) mucosal exposure devices such as the Endorings, Endocap, Endocuff, and G-EYE systems; [73][74][75][76] (ii) image enhancement techniques such as dye chromoendoscopy and virtual chromoendoscopy; [77][78][79][80][81] and (iii) computer-aided polyp detection system (CADe), which is the most promising tool. [82][83][84] By a recent meta-analysis, CADe had the most significant improvement in ADR of ~10% in both low and high ADR detectors and 50% reductions in the missing rate in tandem studies compared to mucosal exposure devices and image enhancement techniques.…”
Section: Quality Improvementmentioning
confidence: 99%
“…water-assisted colonoscopy, right-sided retroflection, double right-side examination, and patient position change during scope withdrawal) have improved ADR. [70][71][72] Additionally, advanced technology aimed at improving ADR can be divided into: (i) mucosal exposure devices such as the Endorings, Endocap, Endocuff, and G-EYE systems; [73][74][75][76] (ii) image enhancement techniques such as dye chromoendoscopy and virtual chromoendoscopy; [77][78][79][80][81] and (iii) computer-aided polyp detection system (CADe), which is the most promising tool. [82][83][84] By a recent meta-analysis, CADe had the most significant improvement in ADR of ~10% in both low and high ADR detectors and 50% reductions in the missing rate in tandem studies compared to mucosal exposure devices and image enhancement techniques.…”
Section: Quality Improvementmentioning
confidence: 99%
“…Endocuff (Arc Medical Design, Leeds, UK) can be used to flatten the colonic folds during withdrawal. There is a significant effect, resulting in higher ADRs [7]. However, Endocuff has to be mounted onto the distal end of the endoscope and can only be removed when the endoscope is outside the patient.…”
mentioning
confidence: 99%