2004
DOI: 10.1183/09031936.04.00138603
|View full text |Cite
|
Sign up to set email alerts
|

Endobronchial ultrasonography with guide-sheath for peripheral pulmonary lesions

Abstract: The usefulness of endobronchial ultrasonography (EBUS) with guidesheath (GS) as a guide for transbronchial biopsy (TBB) for diagnosing peripheral pulmonary lesions (PPL)s and for improving diagnostic accuracy was evaluated in this study.EBUS-GS-guided TBB was performed in 24 patients with 24 PPLs of f30 mm in diameter (average diameter=18.4 mm). A 20-MHz radial-type ultrasound probe, covered with GS was inserted via a working bronchoscope channel and advanced to the PPL in order to produce an EBUS image. The p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

11
153
4

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 188 publications
(168 citation statements)
references
References 25 publications
11
153
4
Order By: Relevance
“…Several studies [5][6][7][8][9][10][11][12] have reported on the efficacy and safety of EBUS-guided transbronchial biopsy. However, no trial has specifically addressed the yield in patients with nodules of f20 mm in diameter.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several studies [5][6][7][8][9][10][11][12] have reported on the efficacy and safety of EBUS-guided transbronchial biopsy. However, no trial has specifically addressed the yield in patients with nodules of f20 mm in diameter.…”
Section: Discussionmentioning
confidence: 99%
“…Several articles have reported the success of EBUS-guided transbronchial biopsy in SPNs [5][6][7][8][9][10][11][12], but, in the most of these trials, SPNs of ,20 mm in diameter were not examined.…”
mentioning
confidence: 99%
“…The following studies reported that the diagnostic yield of EBUS-GS for PPLs was between 57% and 90%, and it was proved to be a safe procedure with low rate of pneumothorax and hemoptysis (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21). Till now there is only one randomized controlled study (22) comparing the two procedures.…”
Section: Introductionmentioning
confidence: 99%
“…The guide sheath remained in position just in front of the lesion (Figure 11). In difficult cases the miniprobe was removed from the guide sheath and a curette was inserted in order to guide the sheath into the lesion (Figure 12) (153). 4.9 Processing the data file in the prospective study…”
Section: Approvals For the Retrospective Studymentioning
confidence: 99%