2018
DOI: 10.1007/s10337-018-3626-x
|View full text |Cite
|
Sign up to set email alerts
|

Enantioseparation of DPP-4 Inhibitors on Immobilized Crown Ether-Based Chiral Stationary Phase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Materials and Methods. Table 3 shows the retention times of unsubstituted aniline (2) and certain substituted anilines (3)(4)(5)(6)(7)(8), (12)(13)(14) under 20 mM neutral phosphate buffer (pH 7.6). Figure 5 shows the retention pattern of substituted aniline isomers and 2-substituted anilines, which exhibited a higher or roughly the same retention in comparison with other isomers.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Materials and Methods. Table 3 shows the retention times of unsubstituted aniline (2) and certain substituted anilines (3)(4)(5)(6)(7)(8), (12)(13)(14) under 20 mM neutral phosphate buffer (pH 7.6). Figure 5 shows the retention pattern of substituted aniline isomers and 2-substituted anilines, which exhibited a higher or roughly the same retention in comparison with other isomers.…”
Section: Resultsmentioning
confidence: 99%
“…In this report, we show the selectivity of a crown ether type CSP, CROWNPAK CR-I (CR-I, Scheme 1 ), for isomeric substituted anilines and the related compounds. This type of CSP is known to have a higher chiral recognition ability for enantiomers having a primary amino group and to be particularly useful for the enantioseparation of natural and non-natural amino acids [ 6 , 7 , 8 , 9 ]. The chiral recognition of chiral crown ethers was developed by Cram et al [ 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…For the investigated amino acids, Br-substituted CSP had the highest chiral recognition ability and it provided a better resolution than the commercially available CSP. For the development and study of the direct enantiomeric separation of alogliptin, linagliptin, and saxagliptin, CROWNPAK CR-I (+) CSP was selected regarding the free amino group content of the investigated dipeptidyl peptidase-4 inhibitors [ 39 ]. Method optimization was performed by studying the effects of the solvent, additive, pH, and column temperature.…”
Section: Recent Applications Of Crown Ether-based Cspsmentioning
confidence: 99%