2013
DOI: 10.1016/j.seppur.2013.08.032
|View full text |Cite
|
Sign up to set email alerts
|

Enantioseparation of atenolol using chiral ligand-exchange chromatography on C8 column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 37 publications
0
13
0
Order By: Relevance
“…This technique of chiral LEC is usually employed in three separate forms: (a) the ‘chiral‐bonded ligand exchanging stationary phases’ where the chiral selector is covalently attached to the stationary phase; (b) ligand exchanging columns that are easily prepared from commercially available reversed‐phase columns by dynamically coating the column with a hydrophobic chiral selector; and (c) the chiral selector predominantly resides in the mobile phase (Alizadeh, ).…”
Section: Enantioresolution By Ligand‐exchange Chromatography (Lec)mentioning
confidence: 99%
See 1 more Smart Citation
“…This technique of chiral LEC is usually employed in three separate forms: (a) the ‘chiral‐bonded ligand exchanging stationary phases’ where the chiral selector is covalently attached to the stationary phase; (b) ligand exchanging columns that are easily prepared from commercially available reversed‐phase columns by dynamically coating the column with a hydrophobic chiral selector; and (c) the chiral selector predominantly resides in the mobile phase (Alizadeh, ).…”
Section: Enantioresolution By Ligand‐exchange Chromatography (Lec)mentioning
confidence: 99%
“…The side chains of both l ‐Ala and ( S )‐Atl in the case of pseudohomochiral complex are on the same side in the space, whereas the side chains of l ‐Ala and ( R )‐Atl in the case of pseudo‐heterochiral complex are on opposite sides. This leads to stronger hydrophobic interactions of the pseudo‐homochiral complex with the stationary phase, leading to longer retention time of ( S )‐Atl, compared with that of ( R )‐Atl (Alizadeh, ).…”
Section: Enantioresolution By Ligand‐exchange Chromatography (Lec)mentioning
confidence: 99%
“…Analytes to be resolved form the mixed-ligand complexes with the selector, which are diastereomeric in their structure. Marfey's reagent UV [118] HPLC Penicillamine TLC Amino acids Marfey's reagent and its chiral variants as CDR UV-340 nm [156] TLC and HPLC Penicillamine Marfey's reagent UV-340 nm [157] TLC and HPLC Non-protein α-amino acids Marfey's reagent and its four variants UV-340 nm [154] Such diastereomers interact differently with the column packing and hence get separated [71][72][73][74]. Schmid et al [75] highlighted their own research developments on chiral separation using the principle of ligand-exchange.…”
Section: Copper (Ii) Amino Acid Complexes As Reagents In Lecmentioning
confidence: 99%
“…k e and k s are the first-order apparent rate constants of the extraction and stripping processes, respectively. The following equations can be proposed for the kinetic model [31]. …”
Section: Effect Of Transport Time and Kinetic Modelingmentioning
confidence: 99%