Enantioselective Determination of Extraterrestrial Amino Acids Using a Two-Dimensional Chiral High-Performance Liquid Chromatographic System

Abstract: A two-dimensional chiral high-performance liquid chromatographic (2D-HPLC) system has been established for the analysis of extraterrestrial amino acids. As the targets, 8 chiral amino acids (alanine (Ala), valine (Val), 2-aminobutyric acid (2AB), norvaline (nVal), N-methylalanine (N-MeAla), isovaline (iVal), 3AB and 3-aminoisobutyric acid (3AIB)) and 5 non-chiral amino acids (glycine (Gly), β-Ala, γ-aminobutyric acid (GABA), sarcosine (Sar) and 2AIB) were selected. These amino acids were tagged with 4-fluoro-7… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2
1

Relationship

3
6

Authors

Journals

citations
Cited by 33 publications
(15 citation statements)
references
References 37 publications
(57 reference statements)
0
15
0
Order By: Relevance
“…Regarding the branched aliphatic amino acids, an anion-exchange type column, Chiralpak QN-AX provided sufficient separations of Val, allo-isoleucine, isoleucine and Leu and their Rs were 2.72-4.29 [33]. The KSAACSP-001S column was also reported to separate a variety of NBD-amino acid enantiomers [34]. In the present investigation, the 7 columns gave complete enantiomer separations of the 3 target aromatic amino acids (Phe, Tyr and DOPA).…”
Section: Establishment Of the 2d-hplc Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding the branched aliphatic amino acids, an anion-exchange type column, Chiralpak QN-AX provided sufficient separations of Val, allo-isoleucine, isoleucine and Leu and their Rs were 2.72-4.29 [33]. The KSAACSP-001S column was also reported to separate a variety of NBD-amino acid enantiomers [34]. In the present investigation, the 7 columns gave complete enantiomer separations of the 3 target aromatic amino acids (Phe, Tyr and DOPA).…”
Section: Establishment Of the 2d-hplc Systemmentioning
confidence: 99%
“…Among these columns, the following 7 columns gave baseline enantiomer separations of all 3 target NBD-amino acids: Pirkle-type columns having amino acid derivatives as chiral selectors (Sumichiral OA-2500S, OA-3100S, OA-3200S, OA-4100SR, OA-4700SR and KSAACSP-001S columns, 1. Until now, the enantiomer separations of NBD-amino acids have been reported using various enantioselective columns including the anion-exchange type, Pirkle-type or teicoplanin bonded chiral stationary phases [32][33][34][35]. By using a Pirkle-type column, OA-2500S, 9 hydrophilic amino acids were separated and their resolution values (Rs) were 1.12-3.52 [32].…”
Section: Establishment Of the 2d-hplc Systemmentioning
confidence: 99%
“…The developmental changes of these D-amino acids are specific to the respective amino acids, and the relationships between their amounts and fermentation/aging processes are expected to be clarified. The 2D-HPLC system is also applicable to the determination of extraterrestrial amino acids [51]. As the target, non-proteinogenic chiral amino acids (2-aminobutyric acid, 3-aminobutyric acid, 3-aminoisobutyric acid, norvaline and isovaline) are also selected, because the contamination from the terrestrial environment is always the problem for proteinogenic amino acids.…”
Section: Application Of the 2d-hplc Analysis Of Amino Acid Enantiomermentioning
confidence: 99%
“…Once carbonaceous materials are contaminated by terrestrial materials, they are difficult to distinguish from each other. In future work, we will establish a state-of-the-art analytical scheme including combustion and/or dissolution methods for the analysis of higher molecular structures, including high-precision, compound-specific measurement of amino acids with the corresponding stereoisomers (Naraoka et al 2012;Hamase et al 2014;Takano et al 2015;Sugahara et al 2018), as well as in situ molecular analysis by desorption electrospray ionization coupled with high-resolution mass spectrometry (Naraoka and Hashiguchi 2018). witness plate (silicon and fluoro rubber), by FE-SEM-EDS, STXM-XANES, and TEM.…”
Section: Future Workmentioning
confidence: 99%