2014
DOI: 10.1117/12.2045516
|View full text |Cite
|
Sign up to set email alerts
|

Enabling technologies for robot assisted ultrasound tomography: system setup and calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…While this approach has a high potential for certain applications, it still requires manual placement of the autonomous holding cage on the patient and does not enable fully automatic scanning. Using two robotic arms holding separate ultrasound probes, a system for 3D robotic tomographic imaging pioneers the idea of localized 3D tomographic ultrasound imaging [29]. With respect to an intra-operative setting, however, the positioning of two robotic arm seems challenging, which is why the major field of applications for this technique might lie in the imaging of smaller structures.…”
Section: B Automatic Data Acquisition Systemsmentioning
confidence: 99%
“…While this approach has a high potential for certain applications, it still requires manual placement of the autonomous holding cage on the patient and does not enable fully automatic scanning. Using two robotic arms holding separate ultrasound probes, a system for 3D robotic tomographic imaging pioneers the idea of localized 3D tomographic ultrasound imaging [29]. With respect to an intra-operative setting, however, the positioning of two robotic arm seems challenging, which is why the major field of applications for this technique might lie in the imaging of smaller structures.…”
Section: B Automatic Data Acquisition Systemsmentioning
confidence: 99%
“…The goal was to design the configuration such that for this cylindrical phantom, the tracker and marker keep line of sight and also the marker remains in the tracker's field of measurement. More details of system components, sample configuration study, and mechanical designs are provided in our previous paper .…”
Section: System Overviewmentioning
confidence: 99%
“…For example, Zhang et al demonstrated the application of a 6-DOF robot with an in-hand 2D US probe that facilitates 3D US volume reconstruction [9]. Aalamifar et al introduced a calibrated robot-assisted US system, which employs visual tracking of movements to follow and align to a manually op-erated probe [10]. US probe calibration has been investigated by incorporating automatic calibration using a 6 degreesof-freedom (DOF) robot, a marker-based optical tracking system, and a US calibration phantom [11], [12].…”
Section: Introductionmentioning
confidence: 99%