2009
DOI: 10.1016/j.jhazmat.2008.06.045
|View full text |Cite
|
Sign up to set email alerts
|

Emission of airborne fibers from mechanically impacted asbestos-cement sheets and concentration of fibrous aerosol in the home environment in Upper Silesia, Poland

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
1
4

Year Published

2010
2010
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(18 citation statements)
references
References 22 publications
(31 reference statements)
1
12
1
4
Order By: Relevance
“…In this study, the concentration of airborne fiber ranged from 0.0022 ± 0.0002 to 0.0038 ± 0.0011 fibers/cc (Table 9). The ranges of airborne fiber in this study remained below the stipulated value for working environments and below (Pastuszka 2009), and far above the concentration recorded by in different buildings in the USA (range between 0.00004 and 0.00011 fibers/cc). Furthermore, the range of airborne fiber recorded in this study almost matched the concentration of asbestos (0.007 fibers/cc) recorded at a construction site by Reynolds et al (1994).…”
Section: Concentration Of Airborne Fiberscontrasting
confidence: 56%
See 1 more Smart Citation
“…In this study, the concentration of airborne fiber ranged from 0.0022 ± 0.0002 to 0.0038 ± 0.0011 fibers/cc (Table 9). The ranges of airborne fiber in this study remained below the stipulated value for working environments and below (Pastuszka 2009), and far above the concentration recorded by in different buildings in the USA (range between 0.00004 and 0.00011 fibers/cc). Furthermore, the range of airborne fiber recorded in this study almost matched the concentration of asbestos (0.007 fibers/cc) recorded at a construction site by Reynolds et al (1994).…”
Section: Concentration Of Airborne Fiberscontrasting
confidence: 56%
“…The determination of airborne fiber on the membrane filter was undertaken through the use of a microscope with a phase contrast (NIOSH 7400). Phase contrast microscopy accurately assessed the level of exposure for fibers 5 μm in length and >0.25 μm in diameter (Pastuszka 2009(Pastuszka , 2010.…”
Section: Sampling Sitesmentioning
confidence: 99%
“…수의 석면시멘트 폐자재를 발생시키고 있다 (Harding et al, 2009 (Spurny, 1989;Ansari et al, 2007;Campopiano et al, 2009;Kakooei et al, 2009;Krakowiak et al, 2009;Pastuszka, 2009), 다양한 기계적 작업 중에 발 생되는 석면섬유 방출에 관한 연구도 진행되었다 (Preat, 1993;Pastuszka, 2009). 우리나라의 경우에는 2000년도 이후에 비산석면 농도 방출에 대한 연구가 있었으며 (Choi et al, 2002;Kim et al, 2009;Kim et al, 2010), 최근에는 토양 중 비산석면 특성에 관한 연구가 진행되었다 (Kwon et al, 2014) …”
Section: 민들의 건강에 잠재적 위험을 끼치고 있으며 상당한unclassified
“…Many studies have been conducted to investigate concentrations and morphology of airborne asbestos fibers in asbestos-containing work places (e.g., Anastasiadou and Gidarakos, 2007;Ansari et al, 2007;Pastuszka, 2009;Kakooei and Marioryad, 2010;Panahi et al, 2011). The results indicated that, generally, the concentrations of asbestos were considerably higher in work places than the permissible asbestos exposure limit in Europe (0.1 fibers/mL) and USA (0.1 fibers/mL) (Directive 83/477/EC, 1983;OSHA, 1998).…”
Section: Introductionmentioning
confidence: 99%