2019
DOI: 10.5152/dir.2019.18556
|View full text |Cite
|
Sign up to set email alerts
|

Emerging clinical applications of high-intensity focused ultrasound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
41
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 53 publications
(41 citation statements)
references
References 87 publications
0
41
0
Order By: Relevance
“…Ultrasound and MRI are two guidance modalities integrated with HIFU, which is an essential prerequisite of HIFU treatment for patient selection, treatment planning, real-time treatment monitoring, safe delivery of the desired therapeutic dose, and treatment efficacy evaluation. Most HIFU treatments are still performed under ultrasound imaging guidance mainly due to its cost-effectiveness and greater accessibility to patients (10).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultrasound and MRI are two guidance modalities integrated with HIFU, which is an essential prerequisite of HIFU treatment for patient selection, treatment planning, real-time treatment monitoring, safe delivery of the desired therapeutic dose, and treatment efficacy evaluation. Most HIFU treatments are still performed under ultrasound imaging guidance mainly due to its cost-effectiveness and greater accessibility to patients (10).…”
Section: Discussionmentioning
confidence: 99%
“…Many patients show clinical symptoms such as menorrhagia, irregular bleeding, pelvic pain, or infertility (4)(5)(6), which have a significant negative effect on their quality of life. Currently, the management for uterine fibroids includes surgery, medicine, uterine artery embolization (UAE), radiofrequency ablation (RFA), ultrasound-guided high-intensity focused ultrasound (USgHIFU), and magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) (7)(8)(9)(10)(11).…”
Section: Introductionmentioning
confidence: 99%
“…authors found that the degree of cell membrane deformation inversely correlated with widening of the bubble-cell membrane gap [28].…”
Section: Mbs Mechanics and Ultrasound Techniquementioning
confidence: 96%
“…Wang et al also studied the impact of bubble-to-cell distance and their interaction using a boundary element method model. The authors found that the degree of cell membrane deformation inversely correlated with widening of the bubble-cell membrane gap [28].…”
Section: Mbs Mechanics and Ultrasound Techniquementioning
confidence: 99%
“…Current noninvasive stimulation techniques, such as transcranial magnetic stimulation (TMS) and transcranial current stimulation (TCS), have shown promising pain reduction effects, despite their limited spatial focality and depth penetration. While high-intensity focused ultrasound mainly achieves its effectiveness through thermal induction or non-thermal ablation, and accomplishes a wide range of clinical applications, [1] low intensity transcranial focused ultrasound (tFUS) has recently emerged as a safe, noninvasive neuromodulation technique with high spatial resolution and focality with capability of accessing the deep brain. Recent efforts on ultrasound neuromodulatory and neurosurgical development have been reviewed with respect to pain diagnosis and treatment mainly at the peripheral nervous system.…”
mentioning
confidence: 99%