2010
DOI: 10.1016/j.sna.2010.08.014
|View full text |Cite
|
Sign up to set email alerts
|

EMA system with gradient and uniform saddle coils for 3D locomotion of microrobot

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
65
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 77 publications
(65 citation statements)
references
References 10 publications
(19 reference statements)
0
65
0
Order By: Relevance
“…force factor = H · ∇ H. (15) As shown in Fig. 2, magnetization in the limited range of the magnetic field is directly related to the magnetic field intensity.…”
Section: ) 3-d Configurationmentioning
confidence: 99%
See 2 more Smart Citations
“…force factor = H · ∇ H. (15) As shown in Fig. 2, magnetization in the limited range of the magnetic field is directly related to the magnetic field intensity.…”
Section: ) 3-d Configurationmentioning
confidence: 99%
“…Furthermore, Mathieu and Martel [11] and Martel et al [12] proposed a system that can generate the force needed to propel magnetic particles inside a magnetic resonance imaging (MRI) device using the electromagnets. Based on MRI concepts, the most recent actuation systems designed for manipulating magnetic particles use two sets of coils for each actuating direction [13]- [15]. In such systems, a set of Helmholtz coils is used to produce a uniform constant magnetic field in the desired direction to magnetize particles, and a set of Maxwell coils is used to generate the gradient magnetic field to produce the necessary magnetophoretic force for propelling magnetic particles.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Gastrointestinal tract driven by microrobot actively is expected in the diagnosis, treatment, spraying, sampling and other medical engineering while MEMS (microelectromechanical systems) technology is combined with the medical technology and application, which will play an important role in the clinical application [1] [2].…”
Section: Introductionmentioning
confidence: 99%
“…Gastrointestinal tract driven by microrobot actively is expected in the diagnosis, treatment, spraying, sampling and other medical engineering while MEMS (micro-electromechanical systems) technology is combined with the medical technology and application, which will play an important role in the clinical application 1,2 . Wireless microrobots are employed in a wide range of biomedical application.…”
mentioning
confidence: 99%