Eltrombopag interferes with the measurement of plasma total bilirubin in pediatric patients in an automated colorimetric method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 5 publications
0
1
0
Order By: Relevance
“…There have been multiple small-scale reports of highdose eltrombopag (200-300 mg daily in adults [7,8,11], 75-150 mg daily in children [12]) causing a reddish-brown discoloration of plasma/serum and discrepant total bilirubin results by automated colorimetric assays. For example, two groups have demonstrated that the Beckman Coulter DxC 800 analyzer is susceptible to producing undetectable levels of total bilirubin in patients on high-dose eltrombopag [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…There have been multiple small-scale reports of highdose eltrombopag (200-300 mg daily in adults [7,8,11], 75-150 mg daily in children [12]) causing a reddish-brown discoloration of plasma/serum and discrepant total bilirubin results by automated colorimetric assays. For example, two groups have demonstrated that the Beckman Coulter DxC 800 analyzer is susceptible to producing undetectable levels of total bilirubin in patients on high-dose eltrombopag [7,8].…”