2020
DOI: 10.1186/s12891-020-03669-5
|View full text |Cite
|
Sign up to set email alerts
|

Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty

Abstract: Background Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw’s trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accurac… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(14 citation statements)
references
References 27 publications
0
14
0
Order By: Relevance
“…When doctors detect a small but significant cup movement they can possibly minimize the incidence of cup loosening and prosthetic hip dislocation. When early cup loosening is detected, we can warn the patient against an excessive range of motion, or take it as a signal for the need of a cup revision [ 4 ]. We would not revise a cup with an anteversion of only 2.5°, but we would pay more attention and advise the patient not to do any extreme internal rotation of hip to prevent dislocation or impingement.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…When doctors detect a small but significant cup movement they can possibly minimize the incidence of cup loosening and prosthetic hip dislocation. When early cup loosening is detected, we can warn the patient against an excessive range of motion, or take it as a signal for the need of a cup revision [ 4 ]. We would not revise a cup with an anteversion of only 2.5°, but we would pay more attention and advise the patient not to do any extreme internal rotation of hip to prevent dislocation or impingement.…”
Section: Discussionmentioning
confidence: 99%
“…However, there was one exception. The standardized Liaw’s anteversion measurement is the only measurement that corrects patient positioning during film acquisition [ 4 , 7 ]. To our knowledge, the standardized Liaw’s measurement is the most accurate method to date [ 4 , 5 , 16 , 17 ].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations