2021
DOI: 10.1109/tim.2020.3013688
|View full text |Cite
|
Sign up to set email alerts
|

Eliminating the Effect of Probe-to-Probe Coupling in Inductive Coupling Method for In-Circuit Impedance Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3
1

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…Fig. 2(b) shows its three-port network (3PN) equivalent circuit [15]. Compared with C2PN equivalent circuit, the 3PN equivalent circuit considers the influence of probe-to-probe coupling between the two inductive probes.…”
Section: Time-domain Two-probe Setupmentioning
confidence: 99%
“…Fig. 2(b) shows its three-port network (3PN) equivalent circuit [15]. Compared with C2PN equivalent circuit, the 3PN equivalent circuit considers the influence of probe-to-probe coupling between the two inductive probes.…”
Section: Time-domain Two-probe Setupmentioning
confidence: 99%
“…Channel 1 (CH1) and channel 2 (CH2) of the signal acquisition card (SAC) of SGAS are used to sample the time-domain voltages at the input of the IIP (𝑽 π‚π‡πŸ ) and the output of the RIP (𝑽 π‚π‡πŸ ), respectively. Unlike the frequency-domain TPS that uses the cascaded two-port network theory, a three-port network theory is used for the time-domain TPS to evaluate the influence of the probe-to-probe coupling from the two inductive probes [55]. The probe-to-probe coupling could result in potential effects on the measurement accuracy of the TPS when the two inductive probes are very close to each other due to space constraints.…”
Section: Inductive Coupling Approachmentioning
confidence: 99%
“…Among the fore mentioned, the latter approach is a preferred method as it has zero physical contact to the live electrical system under test (SUT). Additionally, the clamp-on inductive probes utilised in this method can simply be secured and detached from the insulated cable that transmits power to the SUT which notably simplifies the implementation with minimal electrical risk [7].…”
Section: Introductionmentioning
confidence: 99%
“…The prevailing inductive coupling setup adopts two probes in total: an injecting inductive probe (IIP) and a receiving inductive probe (RIP), which is also known as the Two-Probe Measurement Setup (TPMS). An open/short/load (OSL) calibration procedure is implemented to eradicate any possible ramifications of the probeto-probe coupling [7], however, based on the assumption that the calibration criterions (shorted, open and 50Ξ©) are approximated to their theoretical values in a specified frequency range. Hence, any measurement with frequency outside the specified range (i.e.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation