2013
DOI: 10.1016/j.ijrobp.2012.03.023
|View full text |Cite
|
Sign up to set email alerts
|

Eliminating Inconsistencies in Simulation and Treatment Planning Orders in Radiation Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…The estimation of Θ n and A n is similar to that of the estimation of Θ k and B k shown in Eqs. (5)- (7). Then, the closest distance for each point on the given surface with respect to the fitted GAD model surface is calculated, and the mean distance E i,c of all the surface points on the cth slice is obtained as…”
Section: C Supervised Contouring Error Detection Strategymentioning
confidence: 99%
See 2 more Smart Citations
“…The estimation of Θ n and A n is similar to that of the estimation of Θ k and B k shown in Eqs. (5)- (7). Then, the closest distance for each point on the given surface with respect to the fitted GAD model surface is calculated, and the mean distance E i,c of all the surface points on the cth slice is obtained as…”
Section: C Supervised Contouring Error Detection Strategymentioning
confidence: 99%
“…These errors include mislabeling, missed slices, overlapped structures, isolated voxels or small regions, extremely large or small slices, and structure volume and location distortions. [5][6][7] The contouring errors are major patient safety issues in radiation therapy because they degrade dose distributions, dosimetry analyses, and contour-based visual guidance used in image-guided procedures. [7][8][9][10][11][12] High rates of OAR contouring errors have recently been reported, strongly suggesting the need for effective and practical peer review.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Electronic physician ordering and whiteboard systems are also an effective means for mitigating communication failures. 8,9 Quality control measures for dataset fusion include both automated fusion tools and trained manual inspection. 10 Although automated segmentation tools will be commonplace for online ART to increase efficiency and reduce human error, automated quality control software is necessary for error detection.…”
Section: D Quality Control Strategiesmentioning
confidence: 99%
“…Inconsistencies or poorly chosen naming practices in a radiation oncology clinic may lead to confusion in the interpretation of important details, which may cause patient treatment errors or the misadministration of therapy 13 , 14 , 15 , 16 , 17 . It has been reported in the literature that lack of naming standardization contributes to the incident of event reporting via mechanisms such as PSRS (18) .…”
Section: Introductionmentioning
confidence: 99%