1994
DOI: 10.1109/94.326655
|View full text |Cite
|
Sign up to set email alerts
|

Electrostatic charging in transformer oils. Testing and assessment

Abstract: A B S T R A C TThis review outlines the charging tendency test methods that have been used in the electricity supply industry especially as applied to large transformers. Methods that have been used to generate charge and to measure charge are discussed and the results of various experiments are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2001
2001
2021
2021

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 45 publications
(17 citation statements)
references
References 46 publications
(73 reference statements)
0
17
0
Order By: Relevance
“…The streaming electrification mechanism of mineral oil has already been partially described [11][12][13]. The streaming electrification of oil is caused by the hydroxyl group of the insulating paper molecular structure (Cellulose).…”
Section: Conventional Streaming Electrification Mechanismmentioning
confidence: 99%
“…The streaming electrification mechanism of mineral oil has already been partially described [11][12][13]. The streaming electrification of oil is caused by the hydroxyl group of the insulating paper molecular structure (Cellulose).…”
Section: Conventional Streaming Electrification Mechanismmentioning
confidence: 99%
“…Since 1989, under CIGRE, an international research program of the Working Group 12/15-02 has been implemented [2][3][4]. In the USA, the problem of streaming electrification was dealt with by the Electric Power Research Institute (EPRI) in cooperation with the Massachusetts Institute of Technology (MIT), under the Static Electrification in Power Transformers project [5]. Originally, the ECT research was carried out on transformers subjected to acceptance tests at diagnostic stations [6].…”
Section: Introductionmentioning
confidence: 99%
“…If the relaxation does not eliminate charge quickly enough, a static electrical field can be established, which may end in a static electrical discharge [19], [20]. This phenomenon has been reported as a significant factor in some transformer failures [3], [16], [21]. Static electrification is a function of many parameters including temperature and moisture but primarily the pressboard surface structure and oil condition, specifically the oil electrical charging tendency [22].…”
Section: Static Electrificationmentioning
confidence: 99%