2020
DOI: 10.1021/acsami.0c07447
|View full text |Cite
|
Sign up to set email alerts
|

Electrostatic Air Filtration by Multifunctional Dielectric Heterocaking Filters with Ultralow Pressure Drop

Abstract: In air filtration, for creating healthy indoor air, there is an intrinsic conflict between high filtration efficiency and low wind pressure drop. In this study, we overcame this conflict by developing new dielectric heterocaking (HC) filters, in which high relative dielectric constant (εr) materials were heterogeneously loaded on traditional polymer fibers. The dielectric HC filters in an electrostatic polarizing field generate a great amount of charges on their surface, leading to a strong attraction to prech… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
33
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 22 publications
(35 citation statements)
references
References 54 publications
(102 reference statements)
2
33
0
Order By: Relevance
“…D 2 , the distance between the two mesh electrodes in stage II, will be sufficiently long to prevent any dielectric breakdown discharge (unlike stage I). E 2 promotes 10 2 µm ranged interactions between the polymer fiber and the ( q p , d p ) particle, as well as between the particles (recall Faraday's electric field‐line experiment on forming chains of dielectric particles), [ 30 ] so it becomes easier for the particles to find a fiber surface and attach to it, as well as to agglomerate with other particles and form “dust clusters.” [ 30 ] Given that we would like to operate the filter in high air velocity mode, the dust clusters will be subjected to large shear forces, and may become resuspended if the few Å‐ranged particle–polymer adhesion is not strong enough. Thus, surface engineering of filter fibers to enhance the long‐duration adhesion (up to weeks, and even when U 1 and U 2 are turned off) between the dust cluster and fiber surface is crucial, to prevent dust cluster resuspension and enhance dust‐storage capacity.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…D 2 , the distance between the two mesh electrodes in stage II, will be sufficiently long to prevent any dielectric breakdown discharge (unlike stage I). E 2 promotes 10 2 µm ranged interactions between the polymer fiber and the ( q p , d p ) particle, as well as between the particles (recall Faraday's electric field‐line experiment on forming chains of dielectric particles), [ 30 ] so it becomes easier for the particles to find a fiber surface and attach to it, as well as to agglomerate with other particles and form “dust clusters.” [ 30 ] Given that we would like to operate the filter in high air velocity mode, the dust clusters will be subjected to large shear forces, and may become resuspended if the few Å‐ranged particle–polymer adhesion is not strong enough. Thus, surface engineering of filter fibers to enhance the long‐duration adhesion (up to weeks, and even when U 1 and U 2 are turned off) between the dust cluster and fiber surface is crucial, to prevent dust cluster resuspension and enhance dust‐storage capacity.…”
Section: Resultsmentioning
confidence: 99%
“…This would enable air resistance below 10 Pa at an air filtration velocity of tens of cm s −1 , with a ≈1 cm thick, 200 g m −2 filter. (b)significant E 2 that penetrates the ≈1 cm thick filter interior to cause “Faraday agglomeration” across such ≈10 2 µm pore distance, which we have previously demonstrated with multiple dust particles being observed to form chains, using in situ optical microscopy. [ 30 ] This also requires a strong dielectric response of the fiber in the range of diameter, e.g., ≈10 1 µm. (c)a small and perhaps nonlinear electronic conductivity ( I – V relation) of the fiber to have reasonable antistatic property, [ 33,34 ] so while the monopolar charge q p of a dust particle enhances its long‐range interaction with the fiber, such monopolar charge gets released over a timescale of minutes to hours, allowing this dust particle to later dielectrically bind with other dust particles, which originally carried the same‐signed charges. (d)fiber diameter on the order of ≈10 1 µm, with the expectation that it may become 2 × or 3 × thicker with dust coverings after long‐term filtration operation. Ideally, we would like the filter to be able to trap as much dust as its own weight, meaning ≈10 2 g m −2 dust‐holding capacity.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, this conclusion should not be regarded as a general difference between filter-based air cleaners and electrostatic air cleaners. Tian et al [41][42][43][44] developed electrostatically assisted mechanical filters. Tian et al [45] also presented a comprehensive quality factor (CQF) to evaluate the performance of electrostatic particle removal technologies.…”
Section: Electrostatic Precipitator Vs Mechanical Filtrationmentioning
confidence: 99%