2016
DOI: 10.1097/icu.0000000000000241
|View full text |Cite
|
Sign up to set email alerts
|

Electroretinography in glaucoma diagnosis

Abstract: Purpose of review Electrophysiological measures of vision function have for decades generated interest among glaucoma researchers and clinicians alike because of their potential to help elucidate pathophysiological processes and sequence of glaucomatous damage as well as to offer a potential complementary metric of function that might be more sensitive than standard automated perimetry. The purpose of this article is to review the recent literature in order to provide an update on the role of the electroretino… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
74
2
6

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 87 publications
(84 citation statements)
references
References 65 publications
2
74
2
6
Order By: Relevance
“…The three modes selected were mfERG, ff-ERG and PERG because they have each been evaluated extensively and proven effective in clinical studies of human glaucoma [19,21,13,14,22,23,20,24,15] as well as in previous laboratory studies in NHP eyes after retinal ganglion cell or optic nerve injury [34,28], including EG [35–39,17,40,41,2931]. To our knowledge, however, no prior study has compared all three modes in the same cohort of glaucomatous eyes.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The three modes selected were mfERG, ff-ERG and PERG because they have each been evaluated extensively and proven effective in clinical studies of human glaucoma [19,21,13,14,22,23,20,24,15] as well as in previous laboratory studies in NHP eyes after retinal ganglion cell or optic nerve injury [34,28], including EG [35–39,17,40,41,2931]. To our knowledge, however, no prior study has compared all three modes in the same cohort of glaucomatous eyes.…”
Section: Discussionmentioning
confidence: 99%
“…For these reasons, electrophysiological tests of vision function such as electroretinography (ERG) are thought to have a role in glaucoma management [1315]. ERG testing also provides a non-invasive, objective measure of function that is easier to obtain in laboratory animals than those based on behavioral testing such as perimetry [16,17].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Evidence for a retinal ganglion cell source comes from animal studies showing that the PhNR is reduced or absent in macaques following intravitreal injection of tetrodotoxin as well as in experimentally-induced glaucoma [2,4]. The inner-retina source of the PhNR has made it a useful tool for assessing dysfunction in conditions including glaucoma [3,5–8], optic atrophy [1,9,10], idiopathic intracranial hypertension [11], and optic glioma [12]. …”
Section: Introductionmentioning
confidence: 99%