“…1L) reveals graphitic N/sp 2 C–N bonding at 399.8 eV, amine N at 400.8 eV, and oxidized N at 402.3 eV, respectively. 45 No new chemical bonds were found except for a certain increase in nitrogen content (Table S1†), indicating that PNA might only be physically adsorbed onto the surface of the BBCNs. It was further confirmed by the FT-IR spectra of PNA, BBCNs and the BBCN/PNA complex (Fig.…”
A fluorometric method based on boron, bromide-codoped carbon dots (BBCNs) was firstly developed for the highly selective detection of p-nitroaniline (PNA) in wastewater samples. Note that the introduction of bromine...
“…1L) reveals graphitic N/sp 2 C–N bonding at 399.8 eV, amine N at 400.8 eV, and oxidized N at 402.3 eV, respectively. 45 No new chemical bonds were found except for a certain increase in nitrogen content (Table S1†), indicating that PNA might only be physically adsorbed onto the surface of the BBCNs. It was further confirmed by the FT-IR spectra of PNA, BBCNs and the BBCN/PNA complex (Fig.…”
A fluorometric method based on boron, bromide-codoped carbon dots (BBCNs) was firstly developed for the highly selective detection of p-nitroaniline (PNA) in wastewater samples. Note that the introduction of bromine...
“…Generally, the HOMO–LUMO energy level was measured using the following eqs. 25 E HOMO = −[21.22 − ( E cutoff − E onset )] eV E LUMO = [ E HOMO + E g ] eVwhere the E onset and E cutoff are the positions of the rising and disappearing energy counts within the UPS spectrum, respectively. The UV-vis absorption edge is defined as E g .…”
Section: Resultsmentioning
confidence: 99%
“…16–18 Owing to their lower toxicity, good biocompatibility, and high photostability, we have designed and prepared many CNMs with different physicochemical properties to detect a variety of analytes. 19–25 Inspired by the lack of low toxicity or even non-toxic Mel probes, herein, we develop a simple and eco-friendly synthetic approach toward water-soluble luminescent nano-carbon dots (nano-Cdots) by a one-pot eco-friendly hydrothermal process involving carbon–nitrogen precursors. The entire synthesis process does not involve any toxic reagents.…”
Meloxicam (Mel), as a powerful and effective anti-inflammatory drug, is commonly employed for the treatment of various inflammatory diseases, however, the use of Mel at high-doses or for extended periods...
“…Typically, this is performed using spectroscopic techniques such as fluorescence or absorbance spectroscopy, where a relationship between the quenching process and iodide concentration can be established via calibration. 35 Hu et al 36 utilized a one-pot hydrothermal method with 5-hydroxytryptamine as the sole precursor to synthesize innovative far-ultraviolet emission carbon nanoparticles (FCNPs). The procedure is quick and straightforward and requires no additional hazardous chemicals or solvents.…”
Section: Fluorometric Mechanisms Of Iodide Ion Sensing Using Nanopart...mentioning
Nanomaterial-based sensors have emerged as promising candidates for iodide ions sensing owing to their unique properties, such as high surface area, tunable surface chemistry, and excellent electrical/optical characteristics. Iodide ions...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.