Electron yield X-ray absorption spectroscopy at atmospheric pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
2

Year Published

1991
1991
2011
2011

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 83 publications
(23 citation statements)
references
References 7 publications
(1 reference statement)
0
21
0
2
Order By: Relevance
“…XANES measurements at Sb L 1 edge (4698 eV) were carried out on the E4 station, using as monochromator a Si (1 1 1) double crystal. The XANES data for films were recorded in total electron yield detection mode using the detector developed by Tourillon et al 4 XANES spectra were normalized far from the edge (∼4750 eV) and analyzed in comparison to Sb 2 O 3 and FeSbO 4 references to determine the Sb oxidation in the Sb-doped SnO 2 thin films. EXAFS data were recorded at Sb K edge (30491 eV) and Sn K edge (29200 eV) of ROMO II station at HASYLAB, equipped with a Si (3 1 1) double crystal monochromator which was set to 60% in order to eliminate higher harmonics.…”
Section: Methodsmentioning
confidence: 99%
“…XANES measurements at Sb L 1 edge (4698 eV) were carried out on the E4 station, using as monochromator a Si (1 1 1) double crystal. The XANES data for films were recorded in total electron yield detection mode using the detector developed by Tourillon et al 4 XANES spectra were normalized far from the edge (∼4750 eV) and analyzed in comparison to Sb 2 O 3 and FeSbO 4 references to determine the Sb oxidation in the Sb-doped SnO 2 thin films. EXAFS data were recorded at Sb K edge (30491 eV) and Sn K edge (29200 eV) of ROMO II station at HASYLAB, equipped with a Si (3 1 1) double crystal monochromator which was set to 60% in order to eliminate higher harmonics.…”
Section: Methodsmentioning
confidence: 99%
“…Ion chambers, photodiodes, He-¯ow electron (Tourillon et al, 1987) and¯uorescence (Lytle et al, 1984) detectors have been used in experiments. These detectors and an XY remote-controlled sample holder stand on a 1.60 m-long rail aligned to the beam direction.…”
Section: à4mentioning
confidence: 99%
“…The polarized X-ray absorption spectra were measured by means of the total electron yield detection apparatus and the method described in [21] on the beamline D2 (EXAFSII) at DCI with a positron beam energy of 1.85GeV and a maximum stored current of 285 mA. Data were collected with a two flat Si 311 single crystal monochromator.…”
Section: X-ray Beam and Recording Apparatus Informationmentioning
confidence: 99%