2007
DOI: 10.1021/jp076303y
|View full text |Cite
|
Sign up to set email alerts
|

Electron Transfer from Axial Ligand to S1- and S2-Excited Phosphorus Tetraphenylporphyrin

Abstract: Photoinduced processes of a series of phosphorus tetraphenylporphyrin (PTPP) derivatives ([PTPP-(NHC6H4X)2]+Cl-, X = OCH3, CH3, H, Cl, CF3, and CN) have been investigated by using femtosecond laser flash photolysis mainly. PTPP with OH as an axial ligand showed S2 fluorescence upon excitation of the Soret band. The S2 fluorescence lifetime was estimated to be 1.5 ps. On the other hand, both S2 and S1 fluorescence bands of PTPP-(NHC6H4X)2 were difficult to observe, indicating the existence of an additional deac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
55
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
7
1

Relationship

5
3

Authors

Journals

citations
Cited by 67 publications
(57 citation statements)
references
References 26 publications
2
55
0
Order By: Relevance
“…Steady-state absorption, fluorescence, circular dichroism (CD) spectra, and melting temperature profiles were measured using aS himadzu UV3100PC, Horiba FluoroMax-4P,J ASCO CDJ720, and Shimadzu UV2700, respectively.T he subpicosecond transient absorption spectra were measured by the pump and probe method using ar egeneratively amplified Ti :sapphire laser (Spectra Physics, Spitfire Pro F, 1kHz) pumped by aN d:YLF laser (Spectra Physics, Empower 15). [16] The seed pulse was generated by the Ti :sapphire laser (Spectra Physics, MaiTai VFSJ-W). Samples were excited using the 400 nm laser pulse, which was the second harmonic generation of the output of the amplifier.T he supercontinuum was generated by focusing output of the amplifier on as apphire plate.…”
Section: Resultsmentioning
confidence: 99%
“…Steady-state absorption, fluorescence, circular dichroism (CD) spectra, and melting temperature profiles were measured using aS himadzu UV3100PC, Horiba FluoroMax-4P,J ASCO CDJ720, and Shimadzu UV2700, respectively.T he subpicosecond transient absorption spectra were measured by the pump and probe method using ar egeneratively amplified Ti :sapphire laser (Spectra Physics, Spitfire Pro F, 1kHz) pumped by aN d:YLF laser (Spectra Physics, Empower 15). [16] The seed pulse was generated by the Ti :sapphire laser (Spectra Physics, MaiTai VFSJ-W). Samples were excited using the 400 nm laser pulse, which was the second harmonic generation of the output of the amplifier.T he supercontinuum was generated by focusing output of the amplifier on as apphire plate.…”
Section: Resultsmentioning
confidence: 99%
“…An excitation pulse was generated at 326 nm by an optical parametric amplifier. [24] Fluorescence-decay profiles were measured by the single-photon-counting method using a streakscope. [25] Ultrashort laser pulses were generated by a titanium/sapphire laser.…”
Section: Methodsmentioning
confidence: 99%
“…The subpicosecond transient absorption spectra were measured by the pump and probe method using a regeneratively amplified Ti:sapphire laser (Spectra Physics, Spitfire Pro F, 1 kHz) pumped by a Nd:YLF laser (Spectra Physics, Empower 15). 45 The seed pulse was generated by the Ti:sapphire laser (Spectra Physics, MaiTai VFSJ-W). Samples were excited using the 400 nm laser pulse, which was the second harmonic generation of the output of the amplifier.…”
Section: ■ Introductionmentioning
confidence: 99%