1984
DOI: 10.1002/pssb.2221240244
|View full text |Cite
|
Sign up to set email alerts
|

Electron Paramagnetic Resonance Study of xFe2O3(1‐x)[B2O3 · PbO] Glasses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

1997
1997
2008
2008

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 3 publications
1
9
0
Order By: Relevance
“…In the present study we have not observed the g " 6.0 resonance line because of a relatively large amount of iron present in the samples. It is reported in literature that the resonance at g " 6.0 is observed only in samples with a very low amount of the iron content [38,39]. The g-values observed in the present study indicate that the iron ions are in the trivalent state and the site symmetry is distorted octahedral.…”
Section: Epr Study Of Fe 3+ Ions In Porous Casiosupporting
confidence: 58%
See 1 more Smart Citation
“…In the present study we have not observed the g " 6.0 resonance line because of a relatively large amount of iron present in the samples. It is reported in literature that the resonance at g " 6.0 is observed only in samples with a very low amount of the iron content [38,39]. The g-values observed in the present study indicate that the iron ions are in the trivalent state and the site symmetry is distorted octahedral.…”
Section: Epr Study Of Fe 3+ Ions In Porous Casiosupporting
confidence: 58%
“…The resonance signal at g " 2.0 is due to two or more Fe 3! ions coupled together with dipolar interaction [38,44].…”
Section: Epr Study Of Fe 3+ Ions In Porous Casiomentioning
confidence: 99%
“…Their crystal structures are therefore very similar. Figure 1 illustrates the structure of kaolinite Al 2 [Si 2 O 5 ](OH) 4 . But in montmorillonite and kaolinite structures, the unit cell parameters and symmetry differ very much.…”
Section: Resultsmentioning
confidence: 99%
“…This is because the Debye lines are broad, low intensive and low-resolved for all angles of diffraction. On the other hand, the EPR method turned out to be fruitful due to the anisotropy line 1 [1][2][3][4][5][6][7][8] of intensity increasing with temperature decrease. The resolution of spectral lines increases accordingly.…”
Section: Introductionmentioning
confidence: 99%
“…For the most frequently encountered EPR spectra of Fe 3+ , the typical g-value is close to 2. On the other hand, a resonance line with the g-value close to 4.3 has been analyzed in a number of studies (12)(13)(14)(15) of the EPR spectrum of iron ions in silicate glasses. There is no long-range order in the glasses as well as in the kaolin powder investigated by us.…”
Section: Discussionmentioning
confidence: 99%