2011
DOI: 10.1002/smll.201101484
|View full text |Cite
|
Sign up to set email alerts
|

Electron‐Induced Dynamics of Heptathioether β‐Cyclodextrin Molecules

Abstract: Variable-temperature scanning tunneling microscopy (STM) and spectroscopy (STS) measurements are performed on heptathioether β-cyclodextrin (β-CD) self-assembled monolayers (SAMs) on Au. The β-CD molecules exhibit very rich dynamical behavior, which is not apparent in ensemble-averaged studies. The dynamics are reflected in the tunneling current-time traces, which are recorded with the STM feedback loop disabled. The dynamics are temperature independent, but increase with increasing tunneling current and sampl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 44 publications
0
3
0
Order By: Relevance
“…In this paper, the bandwidth of the current−voltage converter (≈50 kHz) limits our temporal resolution to 20 μs. 38 This motivated us to conduct the present study, in which the dynamics on various phases were studied by recording the current−time spectroscopy with a temporal resolution of 20 μs. (11 × 11 mm 2 , 250 nm Au on 2 nm Cr on borosilicate glass) for STM measurements were purchased from Arrandee (Werther, Germany).…”
Section: ■ Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In this paper, the bandwidth of the current−voltage converter (≈50 kHz) limits our temporal resolution to 20 μs. 38 This motivated us to conduct the present study, in which the dynamics on various phases were studied by recording the current−time spectroscopy with a temporal resolution of 20 μs. (11 × 11 mm 2 , 250 nm Au on 2 nm Cr on borosilicate glass) for STM measurements were purchased from Arrandee (Werther, Germany).…”
Section: ■ Introductionmentioning
confidence: 99%
“…Due to this limitation in temporal resolution, dynamic events are often averaged out. Only a limited number of studies have been performed with a substantially higher time resolution; see, for instance, refs and . The time resolution of a standard STM instrument can be improved by 6–7 orders of magnitude by recording tunnel current–time traces at a preselected position with the feedback loop disabled.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation