2018
DOI: 10.1088/1361-6455/aae6e8
|View full text |Cite
|
Sign up to set email alerts
|

Electron–atom bremsstrahlung cross sections in the 20–100 keV energy region: absolute measurements for $6\leqslant Z\leqslant 79$ and comparison with theoretical databases

Abstract: We report absolute measurements of doubly differential electron-atom bremsstrahlung cross sections for energies in the keV region and elements with atomic numbers 6, 13, 52, 73 and 79. Thin targets were irradiated at the low-energy beam line of the São Paulo Microtron with 20, 50, 75 and 100keV electrons. For each element and energy, the photon spectra were collected simultaneously with three HPGe detectors at the emission angles of 35°, 90°and 131°. The deconvolution of the bremsstrahlung spectra was done ad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0
9

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(19 citation statements)
references
References 37 publications
(122 reference statements)
1
9
0
9
Order By: Relevance
“…This article also provides references to previous absolute measurements for thin solid targets. The results obtained in [9] are consistent with the theoretical data presented in the Refs. [10][11][12].…”
Section: Introductionsupporting
confidence: 92%
See 2 more Smart Citations
“…This article also provides references to previous absolute measurements for thin solid targets. The results obtained in [9] are consistent with the theoretical data presented in the Refs. [10][11][12].…”
Section: Introductionsupporting
confidence: 92%
“…The measurements in Ref. [9] did not observed polarization BS. However, this fact is not surprising, since the atoms of the used targets do not have large polarizabilities in the regions of the BS photon frequencies under consideration.…”
Section: Introductionmentioning
confidence: 78%
See 1 more Smart Citation
“…Por outro lado, quando se calibra o detetor com fontes radioativas, ou quando se coloca um destes detetores em um arranjo de irradiação, normalmente se considera a posição da cápsula alinhada com o material a medir. No caso específico dos trabalhos de Garcia [30,32,34,33], ao saber como estava localizado o cristal na cápsula, esta foi posicionada de forma a compensar o desalinhamento do cristal.…”
Section: Os Detetores De Hpgeunclassified
“…HPGe Planar Ortec 1000 Series Hyperpure Germanuim, com um cristal de 12,5 mm de raio e 10 mm de espessura, janela de entrada de Be de 0,25 mm de espessura. Relacionado aos trabalhos das referências [60,30,34,33]. Este detetor trabalhou conectado a uma eletrônica analógica da ORTEC, composta por: uma fonte de tensão; um amplificador 572 e um multicanal (ASPEC 927).…”
Section: Planar De 5 CCunclassified