2002
DOI: 10.1109/tasc.2002.1018460
|View full text |Cite
|
Sign up to set email alerts
|

Electromagnetic loads on the KSTAR magnet system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…The major functions of the CS structure are both a mechanical support and the pre-compression of ~15 MN 18) . The peak stress including pre-compression is ~500 MPa at the neck part of the inner shell during operation.…”
Section: Magnet Structurementioning
confidence: 99%
“…The major functions of the CS structure are both a mechanical support and the pre-compression of ~15 MN 18) . The peak stress including pre-compression is ~500 MPa at the neck part of the inner shell during operation.…”
Section: Magnet Structurementioning
confidence: 99%
“…However, the peak separation force of 12 MN occurs between PF1 and PF2 coils under several operation conditions. The condition is called as maximum repulsive force (MRF) condition [7], [8]. The designed axial compression of 15 MN at 5 K will be applied partly by assembling the preload structure at room temperature with preload of about 13.4 MN and partly by the thermal contraction difference between CS coils and preload structure during cool down [9].…”
Section: Cs Structurementioning
confidence: 99%
“…The support lug, which is beam-shaped and segmented with insulation, transfers the gravity weight of 21 tons and vertical magnetic force of the CS coils to the TF structure. The peak vertical launching force of the CS magnet system is calculated to be about 2.3 MN at plasma vertical disruption condition [7]. There are eight flexible joints to accommodate the relative radial displacement between the CS and TF magnet systems, which comes from system cool-down and from TF magnet system deformation by in-plane and out-of-plane magnetic forces [11].…”
Section: Cs Structurementioning
confidence: 99%
See 1 more Smart Citation
“…The most important function of CS structures is to protect CS coils from electromagnetic and thermal loads. Specifically, the structures should sustain the high magnetic forces such as hoop forces, vertical attractive and repulsive forces, and lateral forces [3].…”
Section: Introductionmentioning
confidence: 99%