Electromagnetic interference of implantable cardiac devices from a shoulder massage machine

Abstract: Shoulder massage machines have two pads that are driven by solenoid coils to perform a per cussive massage on the shoulders. There have been concerns that such machines might create electromagnetic interference (EMI) in implantable cardiac devices because of the time-varying magnetic fields produced by the alternating current in the solenoid coils. The objective of this study was to investigate the potential EMI from one such shoulder massage machine on implantable cardiac devices. We measured the distribution… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 5 publications
0
4
0
2
Order By: Relevance
“…Therefore, there is an existing and remaining concern of whether NMES can be applied in these patients, due to fear of electromagnetic interference (EMI). EMI can cause oversensing and lead to inappropriate therapies in ICD patients, resulting in arrhythmias and/or painful shocks [2224]. These patients are generally advised to avoid exposure to electrical currents and electromagnetic sources, even though ICDs seem to be less sensitive to interference than pacemakers [25].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, there is an existing and remaining concern of whether NMES can be applied in these patients, due to fear of electromagnetic interference (EMI). EMI can cause oversensing and lead to inappropriate therapies in ICD patients, resulting in arrhythmias and/or painful shocks [2224]. These patients are generally advised to avoid exposure to electrical currents and electromagnetic sources, even though ICDs seem to be less sensitive to interference than pacemakers [25].…”
Section: Introductionmentioning
confidence: 99%
“…Now that there is a current or voltage change, when massage works, the unit will emit EM radiation power disturbance [9]. In view of the actual space, as shown in Fig.…”
Section: Results Analysis and Solutionmentioning
confidence: 99%
“…При анализе причин ЭМИ выделяют пациент-связанные факторы, характеристики физиотерапевтического метода и факторы, связанные с техническими свойствами ИАУ. Так, при определении риска ЭМИ и ее последствий для пациентов, нуждающихся в физиотерапии, необходимо оценить ЭКС-зависимость пациента с помощью пробы с временным отключением ЭКС [23,30] [44,45]. Однако описаны единичные клинические наблюдения, демонстрирующие возникновение ЭМИ, индуцированной ЧЭНС.…”
Section: технические характеристики экс и риск возникновения электромunclassified