2015
DOI: 10.1007/s10800-015-0841-0
|View full text |Cite
|
Sign up to set email alerts
|

Electrolytic ferrate preparation in various hydroxide molten media

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 30 publications
1
5
0
Order By: Relevance
“…Used chemicals included toluene p.a. (Centralchem s.r.o, Slovakia), potassium ferrate (70 %, prepared internally according to the procedure published by Kubiňáková et al, 2015) and distilled water (prepared internally by atmospheric distillation). Instrumental system for the degradation using UV irradiation comprised a reactor equipped with a low-pressure mercury lamp, which provided single line spectra with the wavelength of 254 nm at the power of 10 W. As suitable analytical methods, high-performance liquid chromatography (HPLC) and gas chromatography coupled with mass spectrometry (GC-MS) were chosen.…”
Section: Methodsmentioning
confidence: 99%
“…Used chemicals included toluene p.a. (Centralchem s.r.o, Slovakia), potassium ferrate (70 %, prepared internally according to the procedure published by Kubiňáková et al, 2015) and distilled water (prepared internally by atmospheric distillation). Instrumental system for the degradation using UV irradiation comprised a reactor equipped with a low-pressure mercury lamp, which provided single line spectra with the wavelength of 254 nm at the power of 10 W. As suitable analytical methods, high-performance liquid chromatography (HPLC) and gas chromatography coupled with mass spectrometry (GC-MS) were chosen.…”
Section: Methodsmentioning
confidence: 99%
“…), purity > 98 %, SIGMA-ALDRICH C 8 H 10 N 4 O 2 -caffeine (p.a. ), analytical standard, SIGMA-ALDRICH K 2 FeO 4 -potassium ferrate, electrochemically prepared with the final concentration of nearly 80 % (w/w) (Kubiňáková et al, 2015) Analysis of samples by HPLC The determination was carried out on a HPLC-PDA device detector (model Young Lin 9100). Mobile phase used for the analysis was methanol/water, the ratio of these two phases was gradually changed during the analysis, from the initial value (φ r = 1 : 9) to the final value (φ r = 9 : 1) 16 minutes before the end of the analysis.…”
Section: Methodsmentioning
confidence: 99%
“…Potassium ferrate -electrochemically prepared with the final concentration of nearly 80 % (w/w) (Kubiňáková et al, 2015) C 14 H 10 Cl 2 NNaO 2 -diclofenac sodium (p.a. ), purity at least 96.5 % (w/w), SIGMA-ALDRICH…”
Section: Chemicalsmentioning
confidence: 99%